A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Caution in Using the Activated Partial Thromboplastin Time to Monitor Argatroban in COVID-19 and Vaccine-Induced Immune Thrombocytopenia and Thrombosis (VITT). | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Introduction: Argatroban is licensed for patients with heparin-induced thrombocytopenia and is conventionally monitored by activated partial thromboplastin time (APTT) ratio. The target range is 1.5 to 3.0 times the patients' baseline APTT and not exceeding 100 s, however this baseline is not always known. APTT is known to plateau at higher levels of argatroban, and is influenced by coagulopathies, lupus anticoagulant and raised FVIII levels. It has been used as a treatment for COVID-19 and Vaccine-induced Immune Thrombocytopenia and Thrombosis (VITT). Some recent publications have favored the use of anti-IIa methods to determine the plasma drug concentration of argatroban.

Methods: Plasma of 60 samples from 3 COVID-19 patients and 54 samples from 5 VITT patients were tested by APTT ratio and anti-IIa method (dilute thrombin time dTT). Actin FS APTT ratios were derived from the baseline APTT of the patient and the mean normal APTT.

Results: Mean APTT ratio derived from baseline was 1.71 (COVID-19), 1.33 (VITT) compared to APTT ratio by mean normal 1.65 (COVID-19), 1.48 (VITT). dTT mean concentration was 0.64 µg/ml (COVID-19) 0.53 µg/ml (VITT) with poor correlations to COVID-19 baseline APTT ratio r = 0.1526 p <0.0001, mean normal r = 0.2188 p < 0.0001; VITT baseline APTT ratio r = 0.04 p < 0.001, VITT mean normal r = 0.0064 p < 0.001.

Conclusions: We believe that dTT is a superior method to monitor the concentration of argatroban, we have demonstrated significant differences between APTT ratios and dTT levels, which could have clinical impact. This is especially so in COVID-19 and VITT.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8689594PMC
http://dx.doi.org/10.1177/10760296211066945DOI Listing

Publication Analysis

Top Keywords

aptt ratio
20
baseline aptt
16
aptt
9
activated partial
8
partial thromboplastin
8
thromboplastin time
8
covid-19 vaccine-induced
8
vaccine-induced immune
8
immune thrombocytopenia
8
thrombocytopenia thrombosis
8

Similar Publications