A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

A device to detect leakage at the patient end of total intravenous anaesthesia. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

The use of total intravenous anaesthesia (TIVA) is limited by concerns of disconnections of the tubing, resulting in accidental awareness. We designed a sensor device to detect leakages at the patient end and notify the medical personnel, thereby allowing immediate intervention in preventing awareness. For moisture detection, resistive sensing was selected as the working principle. The prototype was in proximity to the tubing from the TIVA pump and the patient's intravenous cannula, and able to detect leakages in all potential leakage sites and activate an alarm. Our device consists of a disposable bandage (sensor), attached to a reusable clamp that is directly coupled to a central module (SparkFun MicroView, a small microcontroller with built-in Organic Light-Emitting Diode (OLED) display). The disposable bandage is wrapped around the possible leakage sites. Crucially, the disposable bandage is integrated with two separate moisture sensing threads. When moisture is present, the central module detects a drop in resistance across the moisture sensing threads and activates a flashing LED and buzzer. We have successfully created a functional leak detection device, comprising a moisture sensing bandage and an audio and visual alert system, to address the problem of undetected TIVA leakages at the patient end.

Download full-text PDF

Source
http://dx.doi.org/10.1080/03091902.2021.2006349DOI Listing

Publication Analysis

Top Keywords

disposable bandage
12
moisture sensing
12
device detect
8
total intravenous
8
intravenous anaesthesia
8
detect leakages
8
leakages patient
8
leakage sites
8
central module
8
sensing threads
8

Similar Publications