Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

The coronavirus disease 2019 (COVID-19) pandemic unfolded due to the widespread severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) transmission reinforced the urgent need for affordable molecular diagnostic alternative methods for massive testing screening. We present the clinical validation of a pH-dependent colorimetric reverse transcription loop-mediated isothermal amplification (RT-LAMP) for SARS-CoV-2 detection. The method revealed a limit of detection of 19.3 ± 2.7 viral genomic copies/μL when using RNA extracted samples obtained from nasopharyngeal swabs collected in guanidine-containing viral transport medium. Typical RT-LAMP reactions were performed at 65°C for 30 min. When compared to reverse transcriptase-quantitative polymerase chain reaction (RT-qPCR), up to cycle-threshold (Ct) value 32, RT-LAMP presented 98% [95% confidence interval (CI) = 95.3-99.5%] sensitivity and 100% (95% CI = 94.5-100%) specificity for SARS-CoV-2 RNA detection targeting and genes. No cross-reactivity was detected when testing other non-SARS-CoV virus, confirming high specificity. The test is compatible with primary RNA extraction-free samples. We also demonstrated that colorimetric RT-LAMP can detect SARS-CoV-2 variants of concern and variants of interest, such as variants occurring in Brazil named gamma (P.1), zeta (P.2), delta (B.1.617.2), B.1.1.374, and B.1.1.371. The method meets point-of-care requirements and can be deployed in the field for high-throughput COVID-19 testing campaigns, especially in countries where COVID-19 testing efforts are far from ideal to tackle the pandemics. Although RT-qPCR is considered the gold standard for SARS-CoV-2 RNA detection, it requires expensive equipment, infrastructure, and highly trained personnel. In contrast, RT-LAMP emerges as an affordable, inexpensive, and simple alternative for SARS-CoV-2 molecular detection that can be applied to massive COVID-19 testing campaigns and save lives.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8637279PMC
http://dx.doi.org/10.3389/fmicb.2021.713713DOI Listing

Publication Analysis

Top Keywords

covid-19 testing
12
clinical validation
8
colorimetric reverse
8
reverse transcription
8
transcription loop-mediated
8
loop-mediated isothermal
8
isothermal amplification
8
molecular diagnostic
8
detect sars-cov-2
8
sars-cov-2 variants
8

Similar Publications

Background: Effective communication and collaboration among clinical and nonclinical staff are critical to the health and safety of the staff, for optimal team performance and for safe patient care. While respiratory protective equipment are routine key strategies to protect healthcare workers from exposure to select respiratory pathogens, they have been demonstrated to disrupt speech intelligibility. The COVID-19 pandemic escalated the need for and utilization of respiratory protection in all healthcare settings.

View Article and Find Full Text PDF

Objective: The aim of this study was to assess the association between allergic reactions after COVID-19 vaccination and the history of high-risk allergy, individual predisposing factors such as age and gender, and COVID-19 vaccine type.

Materials And Methods: This retrospective cohort study included 234 adult patients (18 years old and above) who underwent a COVID-19 vaccine allergy test up until February 2023 in a Clinic of Allergy and Clinical Immunology in the University Clinical Center of Kosovo. All patients suspected of allergy underwent skin testing: SPT (skin prick test) and IDT (intradermal test) using either an mRNA (ribonucleic messenger acid) vaccine (BNT162b2, Pfizer-BioNTech) and/or an adenoviral vector vaccine (AZD1222, AstraZeneca).

View Article and Find Full Text PDF

Objectives: This study compared the diagnostic accuracy of seven different commercial serological assays for COVID-19, using RT-PCR as the gold standard, through meta-analysis and indirect comparison.

Methods: Fifty-seven studies, published from November 2019 to June 2024, were included. The diagnostic performance of IgA, IgG, and total antibody assays for SARS-CoV-2 was assessed.

View Article and Find Full Text PDF

Background: Few studies have evaluated COVID-19 vaccine effectiveness (VE) in middle-income countries, particularly in eastern Europe. We aimed to estimate COVID-19 VE against SARS-CoV-2-confirmed hospitalizations and severe outcomes in Kosovo.

Methods: We conducted a test-negative case-control study using data from Kosovo's severe acute respiratory infection (SARI) sentinel surveillance system from January 2022 to June 2024.

View Article and Find Full Text PDF

Objective: This study aimed to retrospectively evaluate the prevalence of COVID-19 infection among patients with Parkinson's disease (PD), along with the clinical course and factors associated with mortality.

Methods: A total of 1,786 patients diagnosed with Parkinson's disease and registered at our hospital were screened. Among these, 222 had undergone PCR testing for COVID-19, of whom 76 tested negative and 152 tested positive, indicating a COVID-19 prevalence of 8.

View Article and Find Full Text PDF