Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Although properly designed sampling in population genetic studies is of key importance for planning evidence-informed conservation measures, sampling strategies are rarely discussed. This is the case for the European mink , a critically endangered species. In order to address this problem, a meta-analysis aiming to examine the completeness of mtDNA haplotype sampling in recent studies of inter-population genetic diversity was conducted. The analysis was performed using the sample-size-based rarefaction and extrapolation sampling curve method for three populations-the Northeastern (Russia, Belarus and Estonia), the Western (France and Spain), and the Southeastern (Romania). The extrapolated values of the Shannon-Wiener index were determined, assuming full sample coverage. The gap between the measured and predicted inter-population genetic diversity was estimated, indicating that the identified level of sample coverage was the lowest for the NE population (87%), followed by the SE population (96%) and the W population (99%). A guide for sampling design and accounting for sampling uncertainty in future population genetic studies on European mink is provided. The relatively low sample coverage for the Russian population clearly indicates an urgent need to take conservation measures for European mink in this country.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8535868PMC
http://dx.doi.org/10.3390/genes12101555DOI Listing

Publication Analysis

Top Keywords

european mink
16
inter-population genetic
12
genetic diversity
12
sample coverage
12
gap measured
8
measured predicted
8
predicted inter-population
8
critically endangered
8
population genetic
8
genetic studies
8

Similar Publications

Objective: To develop a set of pediatric neurocritical care (PNCC) entrustable professional activities (EPAs) for pediatric critical care medicine (PCCM).

Design: Survey and Delphi methodology in a panel of experts from the Pediatric Neurocritical Care Research Group (PNCRG) and the Education in Pediatric Intensive Care (EPIC) Research Collaborative.

Setting: Interprofessional local focus group, national focus group, and subsequent national multi-institutional, multidisciplinary expert panel in the United States.

View Article and Find Full Text PDF

Exercise intensity plays a critical role in influencing immune responses during myocarditis, a condition characterized by inflammation of the cardiac tissue. Based on preclinical and clinical evidence, this review examines how moderate high-intensity training affects immune activation in myocarditis. Studies involving animals suggest that moderate exercise may reduce inflammation and support immune regulation, while high-intensity training often exacerbates pro-inflammatory responses and worsens cardiac injury.

View Article and Find Full Text PDF

An Online Buffer Exchange Platform for Charge Detection Mass Spectrometry Analysis of AAVs and AAV-Antibody Complexes.

J Am Soc Mass Spectrom

September 2025

Analytical Chemistry Group, Regeneron Pharmaceuticals Inc., Tarrytown, New York 10591, United States.

Adeno-associated viruses (AAVs) are leading vectors in gene therapy that have demonstrated great potential in combating a wide range of human diseases. To enhance specificity and reduce dosing requirements, antibody-retargeted AAVs have emerged as a promising strategy to redirect vectors to novel receptors, thereby achieving improved efficacy and safety. However, effective characterization of AAVs and AAV-antibody complexes is complicated by heterogeneities that arise from variations in capsid protein assembly, genome integrity, and antibody decorations, demanding high-resolution techniques beyond traditional methods.

View Article and Find Full Text PDF

Nonacog beta pegol (N9-GP) is a glycoPEGylated FIX replacement product with extended half-life for treatment of haemophilia B patients. Monitoring of N9-GP with clotting-based one-stage FIX assays is complicated by high variations, mainly due to reagent-specific interference with polyethylene glycol.In 11 distinct specialized coagulation laboratories in Austria, N9-GP spiked samples were measured in replicates in two distinct surveys, 3 years apart, using five different one-stage assay reagents and one chromogenic FIX assay.

View Article and Find Full Text PDF