A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

A biomechanical study on the effect of lengthening magnitude on spine off-loading in magnetically controlled growing rod surgery: Implications on lengthening frequency. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

To assess whether the magnitude of lengthening in magnetically controlled growing rod (MCGR) surgeries has an immediate or delayed effect on spinal off-loading. 9 whole porcine spines were instrumented using two standard MCGRs from T9 to L5. Static compression testing using a mechanical testing system (MTS) was performed at three MCGR lengthening stages (0 mm, 2 mm, and 6 mm) in each spine. At each stage, five cycles of compression at 175N with 25 min of relaxation was carried out. Off-loading was derived by comparing the load sustained by the spine with force applied by the MTS to the spine. Micro-CT imaging was subsequently performed. The mean load sustained by the vertebral body before lengthening was 39.69N, and immediately after lengthening was 25.12N and 19.91N at 2 mm and 6 mm lengthening, respectively; decreasing to 10.07N, 8.31N, and 8.17N after 25 minutes of relaxation, at 0 mm, 2 mm, and 6 mm lengthening stages, respectively. There was no significant difference in off-loading between 2 mm and 6 mm lengthening stages, either instantaneously ( = 0.395) or after viscoelastic relaxation ( 0.958). CT images showed fractures/separations at the level of pedicle screws in six spines and in the vertebral body's growth zone in five spines after 6 mm MCGR lengthening. This study demonstrated MCGRs cause significant off-loading of the spine leading to stress shielding. 6 mm of lengthening caused tissue damage and microfractures in some spines. There was no significant difference in spine off-loading between 2 mm and 6 mm MCGR lengthening, either immediately after lengthening or after viscoelastic relaxation.

Download full-text PDF

Source
http://dx.doi.org/10.1177/23094990211042237DOI Listing