A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Effect of thermodilution injectate volume and temperature on the accuracy and precision of cardiac output measurements for healthy anesthetized horses. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Objective: To compare the accuracy and precision of cardiac output (CO) measurements derived from 4 thermodilution protocols that used different injectate temperatures and volumes in healthy adult horses.

Animals: 8 healthy adult horses.

Procedures: Horses were anesthetized and instrumented with Swan-Ganz catheters. The CO was derived from each of 4 thermodilution protocols (IV injection of physiologic saline [0.9% NaCl] solution chilled to < 5 °C at volumes of 1 mL/15 kg of body weight [protocol A; control], 1 mL/25 kg [protocol B], and 1 mL/35 kg [protocol C] or maintained at 17 °C at a volume of 1 mL/15 kg [protocol D]) 3 times during each of 5 measurement cycles, with a 30-minute interval between cycles. During each measurement cycle, protocol A was performed first, and protocols B, C, and D were performed in a randomized order. Mean CO and within-subject variance in CO were compared among the 4 protocols.

Results: Mean CO did not differ significantly among the 4 protocols. The within-subject variance for CO measurements derived from protocols C and D, but not protocol B, was significantly greater than that for protocol A (control).

Conclusions And Clinical Relevance: Results suggested that, in healthy adult horses, decreasing the thermodilution injectate volume to 1 mL/25 kg from the recommended volume of 1 mL/15 kg did not adversely affect the accuracy or precision of CO measurements. However, use of smaller injectate volumes or use of injectate at approximately room temperature is not recommended owing to a clinically unacceptable increase in CO measurement variability.

Download full-text PDF

Source
http://dx.doi.org/10.2460/ajvr.82.10.818DOI Listing

Publication Analysis

Top Keywords

accuracy precision
12
healthy adult
12
thermodilution injectate
8
injectate volume
8
precision cardiac
8
cardiac output
8
output measurements
8
measurements derived
8
derived thermodilution
8
thermodilution protocols
8

Similar Publications