A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Optimization of the Transwell System for Assessing the Dissolution Behavior of Orally Inhaled Drug Products through In Vitro and In Silico Approaches. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

The aim of this study was to further evaluate and optimize the Transwell system for assessing the dissolution behavior of orally inhaled drug products (OIDPs), using fluticasone propionate as a model drug. Sample preparation involved the collection of a relevant inhalable dose fraction through an anatomical mouth/throat model, resulting in a more uniform presentation of drug particles during the subsequent dissolution test. The method differed from previously published procedures by (1) using a 0.4 µm polycarbonate (PC) membrane, (2) stirring the receptor compartment, and (3) placing the drug-containing side of the filter paper face downwards, towards the PC membrane. A model developed in silico, paired with the results of in vitro studies, suggested that a dissolution medium providing a solubility of about 5 µg/mL would be a good starting point for the method's development, resulting in mean transfer times that were about 10 times longer than those of a solution. Furthermore, the model suggested that larger donor/receptor and sampling volumes (3, 3.3 and 2 mL, respectively) will significantly reduce the so-called "mass effect". The outcomes of this study shed further light on the impact of experimental conditions on the complex interplay of dissolution and diffusion within a volume-limited system, under non-sink conditions.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8398439PMC
http://dx.doi.org/10.3390/pharmaceutics13081109DOI Listing

Publication Analysis

Top Keywords

transwell system
8
system assessing
8
assessing dissolution
8
dissolution behavior
8
behavior orally
8
orally inhaled
8
inhaled drug
8
drug products
8
dissolution
5
optimization transwell
4

Similar Publications