A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Change in Blood Flow Velocity Pulse Waveform during Plateau Waves of Intracranial Pressure. | LitMetric

Change in Blood Flow Velocity Pulse Waveform during Plateau Waves of Intracranial Pressure.

Brain Sci

Brain Physics Laboratory, Division of Neurosurgery, Department of Clinical Neurosciences, University of Cambridge, Cambridge CB2 0QQ, UK.

Published: July 2021


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

A reliable method for non-invasive detection of dangerous intracranial pressure (ICP) elevations is still unavailable. In this preliminary study, we investigate quantitatively our observation that superimposing waveforms of transcranial Doppler blood flow velocity (FV) and arterial blood pressure (ABP) may help in non-invasive identification of ICP plateau waves. Recordings of FV, ABP and ICP in 160 patients with severe head injury (treated in the Neurocritical Care Unit at Addenbrookes Hospital, Cambridge, UK) were reviewed retrospectively. From that cohort, we identified 18 plateau waves registered in eight patients. A "measure of dissimilarity" (Dissimilarity/Difference Index, DI) between ABP and FV waveforms was calculated in three following steps: 1. fragmentation of ABP and FV signal according to cardiac cycle; 2. obtaining the normalised representative ABP and FV cycles; and finally; 3. assessing their difference, represented by the area between both curves. DI appeared to discriminate ICP plateau waves from baseline episodes slightly better than conventional pulsatility index did: area under ROC curve 0.92 vs. 0.90, sensitivity 0.81 vs. 0.69, accuracy 0.88 vs. 0.84, respectively. The concept of DI, if further tested and improved, might be used for non-invasive detection of ICP plateau waves.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8391497PMC
http://dx.doi.org/10.3390/brainsci11081000DOI Listing

Publication Analysis

Top Keywords

plateau waves
20
icp plateau
12
blood flow
8
flow velocity
8
intracranial pressure
8
non-invasive detection
8
plateau
5
waves
5
icp
5
abp
5

Similar Publications