A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Influence of osteoporosis and mechanical loading on bone around osseointegrated dental implants: A rodent study. | LitMetric

Influence of osteoporosis and mechanical loading on bone around osseointegrated dental implants: A rodent study.

J Mech Behav Biomed Mater

Section of Implant and Rehabilitative Dentistry, Division of Oral Rehabilitation, Faculty of Dental Science, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka, 812-8582, Japan.

Published: November 2021


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

This study aimed to evaluate the influence of estrogen deficiency and mechanical loading on bone around osseointegrated dental implants in a rat jaw model. The maxillary right first molars of 36 rats were extracted. One week later, the rats were divided into an unloaded group and a loaded group; short head implants and long head implants were inserted respectively. Nine weeks after implantation, the rats were further subjected to ovariectomy (OVX) or sham surgery. All animals were euthanized 21 weeks after OVX. Micro-computed tomography, histological and histomorphometrical evaluation were undertaken. Systemic bone mineral density and bone volume fraction decreased in OVX groups compared with the sham controls. Histomorphometrical observation indicated that unloaded OVX group showed significantly damaged osseointegration and bone loss versus the loaded OVX group. Both the bone density (BD) inside the peri-implant grooves and the percentage of bone-to-implant contact (BIC) were lower in the OVX groups than in the sham-surgery groups, although mechanical loading increased the BIC and BD in the loaded OVX group compared with the unloaded OVX group. An increased number of positive cells for tartrate-resistant acid phosphatase was observed in the OVX groups versus the sham controls. The percentage of sclerostin-positive osteocytes was lower under loaded compared with unloaded conditions in both the OVX groups and the sham controls. In conclusion, estrogen deficiency could be a risk factor for the long-term stability of osseointegrated implants, while mechanical loading could attenuate the negative influence of estrogen deficiency on bone formation and osseointegration.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jmbbm.2021.104771DOI Listing

Publication Analysis

Top Keywords

mechanical loading
16
ovx groups
16
ovx group
16
estrogen deficiency
12
sham controls
12
ovx
10
loading bone
8
bone osseointegrated
8
osseointegrated dental
8
dental implants
8

Similar Publications