A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Intra- and Interlaboratory Reproducibility of the Sensitivity to Endocrine Therapy Assay for Stage II/III Breast Cancer. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: The sensitivity to endocrine therapy assay (SET2,3) predicts treatment outcomes in Stage II-III breast cancer. SET2,3 measures transcription related to estrogen and progesterone receptors (SETER/PR index) and the molecular subtype (RNA4: ESR1, PGR, ERBB2, AURKA) from formalin-fixed paraffin-embedded (FFPE) tissue sections.

Methods: We designed a nested study across 3 pathology laboratories, each testing 60 breast cancers twice in controlled batches. Laboratories macrodissected and directly homogenized the unstained FFPE tumor sections, then performed the QuantiGene Plex bead-based hybridization assay. SET2,3 was calculated centrally using predefined statistical R-scripts and applying pre-defined cutpoints. Concordance correlation coefficient (CCC) was calculated from continuous measurements and Kappa statistic from categorical results. A mixed-effects model estimated contributions to bias (fixed effects) and variance (random effects) from the replicated design.

Results: Intralaboratory (CCC 0.96-0.99) and interlaboratory (CCC 0.98-0.99) SET2,3 results were concordant, with rates of agreement for high/low categorization within (Kappa 0.83-0.93) and between laboratories (Kappa 0.87-0.88). The relative contributions to overall variance of SET2,3 measurements were 96.90% from biological differences between cancers, 0.67% from interlaboratory variability, and 2.44% from residual causes including intralaboratory replicates. Similar results were obtained with SETER/PR, the baseline prognostic index calculated using pathological or clinical tumor and nodal staging information, and the 4 individual genes (ESR1, PGR, ERBB2, and AURKA).

Conclusion: Intra- and interpathology laboratory measurements of SET2,3 and its components were highly reproducible when tested from FFPE tumor sections.

Download full-text PDF

Source
http://dx.doi.org/10.1093/clinchem/hvab068DOI Listing

Publication Analysis

Top Keywords

sensitivity endocrine
8
endocrine therapy
8
therapy assay
8
breast cancer
8
assay set23
8
esr1 pgr
8
pgr erbb2
8
ffpe tumor
8
tumor sections
8
set23
6

Similar Publications