A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Clinical translation of hyperpolarized C pyruvate and urea MRI for simultaneous metabolic and perfusion imaging. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Purpose: The combined hyperpolarized (HP) C pyruvate and urea MRI has provided a simultaneous assessment of glycolytic metabolism and tissue perfusion for improved cancer diagnosis and therapeutic evaluation in preclinical studies. This work aims to translate this dual-probe HP imaging technique to clinical research.

Methods: A co-polarization system was developed where [1- C]pyruvic acid (PA) and [ C, N ]urea in water solution were homogeneously mixed and polarized on a 5T SPINlab system. Physical and chemical characterizations and toxicology studies of the combined probe were performed. Simultaneous metabolic and perfusion imaging was performed on a 3T clinical MR scanner by alternatively applying a multi-slice 2D spiral sequence for [1- C]pyruvate and its downstream metabolites and a 3D balanced steady-state free precession (bSSFP) sequence for [ C, N ]urea.

Results: The combined PA/urea probe has a glass-formation ability similar to neat PA and can generate nearly 40% liquid-state C polarization for both pyruvate and urea in 3-4 h. A standard operating procedure for routine on-site production was developed and validated to produce 40 mL injection product of approximately 150 mM pyruvate and 35 mM urea. The toxicology study demonstrated the safety profile of the combined probe. Dynamic metabolite-specific imaging of [1- C]pyruvate, [1- C]lactate, [1- C]alanine, and [ C, N ]urea was achieved with adequate spatial (2.6 mm × 2.6 mm) and temporal resolution (4.2 s), and urea images showed reduced off-resonance artifacts due to the J coupling.

Conclusion: The reported technical development and translational studies will lead to the first-in-human dual-agent HP MRI study and mark the clinical translation of the first HP C MRI probe after pyruvate.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8616838PMC
http://dx.doi.org/10.1002/mrm.28965DOI Listing

Publication Analysis

Top Keywords

pyruvate urea
16
clinical translation
8
hyperpolarized pyruvate
8
urea mri
8
simultaneous metabolic
8
metabolic perfusion
8
perfusion imaging
8
combined probe
8
[1- c]pyruvate
8
pyruvate
5

Similar Publications