A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Effects of Corneal Biomechanical Properties on Rebound Tonometry (Icare200) and Applanation Tonometry (Perkins) Readings in Patients With Primary Congenital Glaucoma. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Objective: The aim was to assess the influence of corneal biomechanics on intraocular pressure (IOP) measurements made with the Icare200 (IC200) rebound tonometer and the Perkins handheld applanation tonometer in patients with primary congenital glaucoma (PCG).

Materials And Methods: A total of 40 PCG patients and 40 healthy controls, age, and sex-matched, were recruited. IOP was measured with the Ocular Response Analyzer (IOPc, IOPg), IC200 and Perkins. The variables age, IOP, corneal hysteresis (CH), corneal resistance factor (CRF), central corneal thickness (CCT), best-corrected visual acuity, spherical equivalent, medications, and glaucoma surgeries were recorded for each subject. Univariate and multivariate analysis were used to detect effects of variables on IOP measurements.

Results: Mean CCT was 545.65±71.88 μm in PCG versus 558.78±27.58 μm in controls (P=0.284). CH and CRF were significantly lower in PCG group than in control group: mean CH 8.11±1.69 versus 11.15±1.63 mm Hg (P<0.001), and mean CRF 9.27±2.35 versus 10.71±1.75 mm Hg (P=0.002). Mean differences between IOP IC200-Perkins were 0.79±0.53 mm Hg in PCG versus 0.80±0.23 mm Hg in controls (P<0.001) and mean differences IC200-IOPc were -0.89±5.15 mm Hg in PCG (P<0.001) versus 1.60±3.03 mm Hg in controls (all P<0.009). Through multivariate analysis, CRF showed positive association and CH negative association with IOP measured with Perkins or IC200 in both subject groups. No association was detected for CCT, age, or sex.

Conclusion: CH and CRF were identified as the main factors interfering with IOP measurements made with both tonometers in patients with PCG and healthy controls.

Download full-text PDF

Source
http://dx.doi.org/10.1097/IJG.0000000000001913DOI Listing

Publication Analysis

Top Keywords

patients primary
8
primary congenital
8
congenital glaucoma
8
effects corneal
4
corneal biomechanical
4
biomechanical properties
4
properties rebound
4
rebound tonometry
4
tonometry icare200
4
icare200 applanation
4

Similar Publications