98%
921
2 minutes
20
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1080/09553002.2021.1942710 | DOI Listing |
J Endod
September 2025
Dental Specialty Center, Brazilian Military Police, Minas Gerais, Brazil.
Introduction: To evaluate how stepwise enlargement in the mesial root canals of mandibular first molars affect shaping outcomes and irrigant dynamics.
Methods: The shaping ability and irrigant flow patterns in mesial canals of mandibular first molars enlarged with ProTaper Next instruments (25/.06v, 30/.
Med Phys
September 2025
Image X Institute, Faculty of Medicine and Health, University of Sydney, Eveleigh, New South Wales, Australia.
Introduction: Prospective hazard analysis (PHA) was introduced to the wider medical physics community by the initiation of American association of physicists in medicine task group 100 in 2003. Since then, there has been increasing interest in the applicability of PHA to radiotherapy for the purpose of keeping patients safe and assessing the risks within the whole practice of radiotherapy. The purpose of this research was to review the PHA literature focusing on which techniques and technologies have been assessed, how they have been assessed, and what can be learnt.
View Article and Find Full Text PDFJ Appl Clin Med Phys
September 2025
Icon Cancer Centre Toowoomba, Toowoomba, Queensland, Australia.
Introduction: The role of imaging in radiotherapy is becoming increasingly important. Verification of imaging parameters prior to treatment planning is essential for safe and effective clinical practice.
Methods: This study described the development and clinical implementation of ImageCompliance, an automated, GUI-based script designed to verify and enforce correct CT and MRI parameters during radiotherapy planning.
J Appl Clin Med Phys
September 2025
Clinical Imaging Physics Group, Duke University Health System, Durham, North Carolina, USA.
Introduction: Medical physicists play a critical role in ensuring image quality and patient safety, but their routine evaluations are limited in scope and frequency compared to the breadth of clinical imaging practices. An electronic radiologist feedback system can augment medical physics oversight for quality improvement. This work presents a novel quality feedback system integrated into the Epic electronic medical record (EMR) at a university hospital system, designed to facilitate feedback from radiologists to medical physicists and technologist leaders.
View Article and Find Full Text PDFG Ital Nefrol
August 2025
Professor, Department of Radio Diagnosis, SRM Medical College Hospital and Research Centre, SRM Institute of Science and Technology, Kattankulathur, 603203, Chengalpattu District, Tamil Nadu, India.
Contrast-induced nephropathy (CIN), often referred to as post-contrast acute kidney injury (PC-AKI), remains a significant issue in diagnostic imaging procedures that utilize iodinated contrast agents. This study aims to examine the knowledge, perceptions, and practices of radiologists and radiographers regarding PC-AKI. A survey was conducted among South Indian radiologists and radiographers in November and December of 2024.
View Article and Find Full Text PDF