Cusp-overlapping TAVI technique with a self-expanding device optimizes implantation depth and reduces permanent pacemaker requirement.

Rev Esp Cardiol (Engl Ed)

Área del Corazón, Hospital Universitario Central de Asturias, Oviedo, Spain; Instituto de Investigación del Principado de Asturias, Oviedo, Spain; Departamento de Medicina, Facultad de Medicina, Universidad de Oviedo, Oviedo, Spain.

Published: May 2022


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Introduction And Objectives: This study aimed to determine the safety and efficacy of modifying the classic implantation technique for aortic transcatheter heart valve (THV) implantation to a cusp-overlap-projection (COP) technique to achieve a higher implantation depth and to reduce the burden of new permanent pacemaker implantation (PPMI) at 30 days. Aortic self-expanding THV carries an elevated risk for PPMI. A higher implantation depth minimizes the damage in the conduction system and may reduce PPMI rates.

Methods: From March 2017, 226 patients were consecutively included: 113 patients were treated using the COP implantation technique compared with the previous 113 consecutive patients treated using the classic technique. In all patients, implantation depth was assessed by 3 methods (noncoronary cusp to the THV, mean of the noncoronary cusp and the left coronary cusp to the THV, and the deepest edge from the left coronary cusp and the noncoronary cusp to the THV).

Results: The COP group had a lower implantation depth than the group treated with the classic technique (4.8 mm± 2.2 vs 5.7 mm± 3.1; P=.011; 5.8 mm± 3.1 vs 6.5 mm± 2.4; P=.095; 7.1 mm± 2.8 vs 7.4 mm±3.2; P=.392). Forty patients (17.7%) required a new PPMI after the 30-day follow-up but this requirement was significantly lower in the COP group (12.4% vs 23%, P=.036). The COP implantation technique consistently protected against the main event (OR, 0.45; 95%CI, 0.21-0.97; P=.043), with similar procedural success rates and complications.

Conclusions: The COP implantation technique is a simple modification of the implantation protocol and provides a higher implantation depth of self-expanding-THV with lower conduction disturbances and PPMI rates.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.rec.2021.05.009DOI Listing

Publication Analysis

Top Keywords

implantation depth
24
implantation technique
16
implantation
13
higher implantation
12
cop implantation
12
noncoronary cusp
12
technique
8
permanent pacemaker
8
patients treated
8
treated classic
8

Similar Publications

Objective: Aim: To evaluate the possibility of using cataract phacoemulsification with simultaneous intraocular lens (IOL) implantation in patients with age-related cataract (ARC) combined with pseudoexfoliation syndrome (PES) as an algorithm for the pseudoexfoliation glaucoma (PEG) prevention..

Patients And Methods: Materials and Methods: A retrospective case-control study was conducted using data from medical records of 610 outpatients (813 eyes) with ARC aged from 49 to 79 years (average age 69 ± 3 years).

View Article and Find Full Text PDF

Purpose: To report clinical outcomes in patients implanted with an isofocal optic-design intraocular lens (IOL) with double C-loop haptics following cataract surgery.

Methods: This was a multicentre-prospective-study involving 108 eyes (54 subjects) implanted with the Isopure Serenity (BVI, Inc). IOL.

View Article and Find Full Text PDF

Rapid Atrial Pacing After TAVI for Pacemaker Prediction.

Rev Cardiovasc Med

August 2025

Heart Rhythm Management Centre, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel - Vrije Universiteit Brussel, European Reference Networks Guard-Heart, 1090 Brussels, Belgium.

Despite continued advancements in transcatheter aortic valve implantation (TAVI) techniques, the incidence of permanent pacemaker implantation (PPI) remains substantial. Established predictors of PPI include advanced age, pre-existing electrocardiographic conduction abnormalities, prosthetic valve type, implantation depth, and anatomical parameters, such as membranous septum length, which are currently under active investigation. In routine clinical practice, the management strategy often involves the temporary placement of a transvenous pacemaker lead, followed by a period of observation.

View Article and Find Full Text PDF

Purpose: To evaluate tilt, decentration, and axial stability of the Clareon toric intraocular lens (TIOL) (CNW0T3-9; Alcon Laboratories, Inc) over a 6-month follow-up period.

Methods: A single-center, prospective, interventional clinical trial was conducted with a study population of 130 eyes from 82 patients who received a Clareon TIOL. Tilt, decentration, and the aqueous depth were determined preoperatively and at 1 week and 6 months postoperatively using anterior segment optical coherence tomography (Casia 2; Tomey Corporation).

View Article and Find Full Text PDF

Purpose: To evaluate visual and refractive outcomes, visual quality, patient satisfaction, and spectacle independence 3 months after phacoemulsification with bilateral non-diffractive enhanced depth of focus (EDOF) lens implantation.

Methods: This study included 68 eyes of 34 consecutive patients, with 51.5% undergoing refractive lens exchange and 48.

View Article and Find Full Text PDF