Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: Aniridia patients have poor visual acuity and iris malformation. The fovea in these patients is underdeveloped, but the relationship between structure and electrophysiologic function remains incompletely understood. This study correlates electrophysiology, visual acuity and optical coherence tomography (OCT) in patients with aniridia secondary to mutations in the PAX6 gene and compares with age-similar controls.

Methods: Patients were recruited from clinical practice. The mfERG protocol was a 4-min 103-hexagon protocol covering approximately 40° in diameter of central retina. Diagnosys full-field ERG (ffERG) and VERIS multifocal ERG (mfERG) were obtained using standard International Society for Clinical Electrophysiology of Vision protocols. OCT central thickness was recorded, and an OCT foveal score was calculated. Nonparametric permutation testing was utilized to determine the statistical significance.

Results: A total of 6 aniridia patients and 25 control patients were recruited. On mfERG, aniridia patients had significantly lower amplitudes in rings 1-3 (p = 0.0006, 0.0013, 0.0132), shorter latencies in ring 1 (p = 0.0312) and longer latencies in rings 5 and 6 (p = 0.0026, p = 0.0042) than controls. There was a significantly positive relationship in aniridia patients between logMAR visual acuity and mfERG amplitude in ring 4 (p = 0.0392) and ring 5 (p = 0.0489). On ffERG, there was no difference in amplitudes, though photopic 3.0 a- and b-wave latency, 30 Hz flicker latency and scotopic 0.01 b-wave latency were significantly longer in aniridia patients versus control (p = 0.0018, 0.0.0005, 1.00 x [Formula: see text], 0.0198). Thicker central macula on OCT correlated with lower mfERG amplitudes in rings 4-6 (p = 0.0369, 0.0292, 0.0255). There was no correlation between visual acuity and central macular thickness or foveal hypoplasia score as determined by OCT.

Conclusions: Higher amplitude on mfERG correlated with poorer visual acuity in rings 4 and 5 in patients with PAX6 mutations. The slope of the change in amplitude from central to peripheral rings on the mfERG is significantly different in aniridia patients compared to controls, with a slower drop-off of amplitude from center to periphery. Additionally, mfERG in aniridia showed lower amplitudes than controls in rings 1-3. These changes along with the lack of correlation between visual acuity and central macular thickness/OCT score suggest that changes in electrical topography may be important to visual deficits in patients with PAX6 gene mutations.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10633-021-09844-wDOI Listing

Publication Analysis

Top Keywords

visual acuity
28
aniridia patients
24
patients
12
mferg aniridia
12
aniridia
9
visual
8
pax6 mutations
8
pax6 gene
8
patients recruited
8
mferg
8

Similar Publications

Introduction: This study aimed to assess visual and refractive outcomes and cost utility of toric intraocular lens (IOLs) implantation in cataract patients over 80 with corneal astigmatism.

Methods: Patients >= 80 years with corneal astigmatism >= 1.50 diopters (D) who underwent cataract surgery with toric or monofocal IOLs were enrolled.

View Article and Find Full Text PDF

Clinical Relevance: Good vision is critical for childhood development and education. Pre-school vision screening is important for early detection and treatment of visual problems, and prevention of life-long vision loss.

Background: The aim of this study was to determine the prevalence of vision impairment (VI) and refractive error (RE) in rural Nepalese children under five years of age.

View Article and Find Full Text PDF

Purpose: To demonstrate the efficacy and safety of iris-claw phakic intraocular lens (pIOL) in the treatment of post keratoplasty astigmatism.

Setting: Cornea Unit, Ophthalmology Department - Unidade Local de Saúde de Santo António - Porto, Portugal.

Design: Retrospective longitudinal study.

View Article and Find Full Text PDF

Topic: To compare the outcomes of surgical approaches to correct ametropia following cataract and lens surgery.

Clinical Relevance: Despite advancements in the field of biometry and intraocular lens (IOL) power calculation formulas, complete elimination of refractive surprises following cataract and lens surgery is impossible. Preferred Practice Patterns acknowledges the possibility of refractive surprise following cataract surgery; however, no recommendations regarding the preferred treatment have been given.

View Article and Find Full Text PDF

Purpose: To report a case of late dehiscence of an EndoArt implant and its successful management 10 months after initial implantation.

Methods: Case report.

Results: A 73-year-old man with a history of multiple failed Descemet membrane endothelial keratoplasty procedures on the right eye underwent EndoArt implantation for bullous keratopathy.

View Article and Find Full Text PDF