Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

The wear comfort of a prosthesis is of great importance for amputee patients. The wear comfort can be affected by changes in the interface between the residual limb and prosthesis socket, which can be caused by time-dependent volume fluctuations of the tissue, leading to unwanted local pressure marks. The basis to ensure time-independent wear comfort of a prosthesis is to identify these changes. Common techniques for identifying these variations have a negative impact on the sensitive interface between the residual limb and prosthesis. The following paper contains a proof of concept for the detection of local pressure marks without affecting the described interface using structural dynamics measurements, exemplarily shown at a prosthetic socket for transfemoral amputees in a test bench scenario. The dynamical behaviour of the investigated system is analysed in the form of frequency response functions acquired for different pressure locations and preloads using an impact hammer for excitation and a triaxial acceleration sensor. The frequency response functions show major changes for the various boundary conditions with respect to their frequency-dependent compositions. The results demonstrate how the utilised method enables the identification of changes in local pressure marks regarding the variation of position and magnitude.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8198458PMC
http://dx.doi.org/10.3390/s21113821DOI Listing

Publication Analysis

Top Keywords

local pressure
16
pressure marks
16
wear comfort
12
proof concept
8
concept detection
8
detection local
8
structural dynamics
8
comfort prosthesis
8
interface residual
8
residual limb
8

Similar Publications

Acute lymphoblastic leukemia (ALL) preferentially localizes in the bone marrow (BM) and displays recurrent patterns of medullary and extra-medullary involvement. Leukemic cells exploit their niche for propagation and survive selective pressure by chemotherapy in the BM microenvironment, suggesting the existence of protective mechanisms. Here, we established a three-dimensional (3D) BM mimic with human mesenchymal stromal cells and endothelial cells that resemble vasculature-like structures to explore the interdependence of leukemic cells with their microenvironment.

View Article and Find Full Text PDF

Among the different forms of hydrotherapy, carbon dioxide (CO) water immersion improves peripheral vasodilation and blood flow compared with tap water immersion; however, the heat stress placed on the body through CO water immersion and the appropriate immersion protocols are uncertain. Therefore, this study aimed to compare the thermoregulatory responses during CO and tap water immersions. The participants were 10 male college baseball players.

View Article and Find Full Text PDF

Leading through expertise: a qualitative study of clinicians' experience of a paediatric clinical trial for displaced medial epicondyle fracture.

Bone Jt Open

September 2025

Kadoorie, Oxford Trauma and Emergency Care, Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, Oxford University, Oxford, UK.

Aims: We sought to explore staff experience of a paediatric randomized controlled trial (RCT), comparing operative fixation and nonoperative treatment for displaced medial epicondyle fractures.

Methods: A total of 20 staff (eight surgeons and 12 research delivery staff) recruiting to the RCT in 18 NHS Trusts across the UK took part in a telephone/online qualitative interview. Interviews were informed by Heideggerian Phenomenology and thematic analysis.

View Article and Find Full Text PDF

Airborne bioaerosol transmission in hospital waiting corridor: Characteristic, exposure risk and evaluation of prevention strategies.

J Hazard Mater

September 2025

State Key Laboratory of Respiratory Disease, National Clinical Research Center for Respiratory Disease, Guangzhou Institute of Respiratory Health, The First Affiliated Hospital of Guangzhou Medical University, Guangzhou 510120, China.

Following the global COVID-19 pandemic, greater attention has been paid to public health safety, especially in hospital environments. In waiting areas with interconnected spaces, complex airflow, unclear bioaerosol dispersion, and the limitations of traditional control methods pose major challenges. This study combined real-world experiments and numerical simulations to investigate the airborne transmission characteristics of pathogen-laden aerosols in a hospital waiting corridor.

View Article and Find Full Text PDF

We report the structural, electrical, and magnetic properties of the organic conductor κ-(BEST)Cu(CN) (BEST: bis(ethylenediseleno)-tetrathiafulvalene; abbreviated as κ-BEST-CN), which is isostructural with the quantum spin liquid candidate κ-(ET)Cu(CN) (ET: bis(ethylenedithio)tetrathiafulvalene; abbreviated as κ-ET-CN). Resistivity measurements demonstrate that κ-BEST-CN exhibits semiconducting behavior, governed by the same conducting mechanism as κ-ET-CN. Under a pressure of ∼0.

View Article and Find Full Text PDF