A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Development and Validation of a Sensitive GC-MS/MS Method for the Determination of Five Potential Genotoxic Impurities in Abiraterone Acetate. | LitMetric

Development and Validation of a Sensitive GC-MS/MS Method for the Determination of Five Potential Genotoxic Impurities in Abiraterone Acetate.

J Chromatogr Sci

Jiangxi Institute for Drug Control, NMPA Key Laboratory of Quality Evaluation of Traditional Chinese Patent Medicine, Jiangxi Province Engineering Research Center of Drug and Medical Device Quality, 1566 East Beijing Road, NanChang 330029, Jiangxi, China.

Published: February 2022


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

A sensitive and selective gas chromatography-tandem mass spectrometry method was developed for the identification and quantification of five potential genotoxic impurities (PGIs), i.e., chloromethane, 2-chloropropane, 2-bromopropane, 4-chloro-1-butanol and diethyl sulfate, in abiraterone acetate. The method was validated according to the International Council for Harmonisation (ICH) guidelines. The linearity was established for the concentration range of 30-480 ng/mL (2-chloropropane, 2-bromopropane, 4-chloro-1-butanol and diethyl sulfate) and 90-1440 ng/mL (chloromethane). The correlation coefficient of each PGIs was >0.995. The extraction recoveries ranged from 90.49 to 106.79% for the five PGIs. The quantitation limit, detection limit, accuracy, precision, repeatability and stability of the method demonstrated that the method was an adequate quality control tool for quantitation and identification of chloromethane, 2-chloropropane, 2-bromopropane, 4-chloro-1-butanol and diethyl sulfate at trace levels in drug substances and drug products.

Download full-text PDF

Source
http://dx.doi.org/10.1093/chromsci/bmab052DOI Listing

Publication Analysis

Top Keywords

2-chloropropane 2-bromopropane
12
2-bromopropane 4-chloro-1-butanol
12
4-chloro-1-butanol diethyl
12
diethyl sulfate
12
potential genotoxic
8
genotoxic impurities
8
abiraterone acetate
8
chloromethane 2-chloropropane
8
method
5
development validation
4

Similar Publications