Assessment of Insertion Torque of Mini-implant and Its Correlation with Primary Stability and Pain Levels in Orthodontic Patients.

J Contemp Dent Pract

Department of Orthodontics, Saveetha Dental College and Hospital Saveetha Institute of Medical and Technical Sciences, Saveetha University, Chennai, Tamil Nadu, India.

Published: January 2021


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Aim: The aim of this study was to assess the insertion torque of the mini-implant used in orthodontic patients and to assess the correlation between the insertion torque, primary stability, and perception of pain in patients undergoing orthodontic therapy with mini-implant-augmented anchorage.

Material And Methods: Among the patients undergoing orthodontic therapy, 31 samples who required mini-implant for anchorage purpose were selected. A total of 59 mini-implants were placed in these patients. This included interradicular mini-implants and extra-alveolar mini-screws. Immediately after placement, the insertion torque in all these was measured using a digital torque meter and primary stability was assessed by identifying any mobility of the implant placed. Primary stability was noted at two time intervals immediate post-placement and 1 week after that. All the mini-implants that were considered in this study were immediately loaded. Patients were asked to record any pain experienced on the visual analog scale (VAS) score sheet at 24 hours and 1 week post-placement.

Results: Among the mini-implants placed, those with 2 mm diameter needed higher placement torque, i.e., infrazygomatic crest mini-implants and buccal shelf mini-implants were placed with average placement torque of 10.08 and 10.25 N cm, respectively. Extra-alveolar screws caused more pain, especially higher in the mandible than the maxilla. Decrease in pain scores was noted from T0 to T1 in almost all the cases.

Conclusion: Thicker mini-implant needed more insertion torque and highest insertion torque was recorded with extra-alveolar screws. No direct correlation could be obtained with the pain levels experienced by the patients and with the primary stability of the mini-implants.

Clinical Significance: Mini-implants placed with an insertion torque above the recommended range tend to fail and break more often. Patients placed with extra-alveolar bone screws reported more pain than that of the smaller-dimension mini-implant.

Download full-text PDF

Source

Publication Analysis

Top Keywords

insertion torque
28
primary stability
20
torque
10
torque mini-implant
8
pain levels
8
patients
8
orthodontic patients
8
patients undergoing
8
undergoing orthodontic
8
orthodontic therapy
8

Similar Publications

The 180° switching of the perpendicular Néel vector induced by the spin-orbit torque (SOT) presents significant potential for ultradense and ultrafast antiferromagnetic SOT-magnetoresistive random-access memory. However, its experimental realization remains a topic of intense debate. Here, unequivocal evidence is provided for the SOT-induced 180° switching of the perpendicular Néel vector in collinear antiferromagnetic CrO in a Pt/CrO/Co trilayer structure.

View Article and Find Full Text PDF

Purpose: To evaluate changes in implant stability quotient values of hydrophilic tissue-level implants over time, and to investigate the influence of local factors on variations in these values.

Methods: Fifty tapered, self-tapping, tissue-level implants with a hydrophilic surface were placed and monitored for 12 months. Implant stability quotient values were recorded at the time of insertion (T0) and monthly thereafter for 12 months.

View Article and Find Full Text PDF

Introduction: Screw loosening remains a frequent mechanical complication in implant-supported prostheses, primarily caused by the gradual loss of abutment-screw preload. The aim of this study was to evaluate the mechanical performance of CAD-CAM custom and stock abutments by measuring removal torque values (RTV) at multiple time points and assessing surface morphology by scanning electron microscopy (SEM), following prolonged loading up to 2 × 10 cycles.

Methods: Forty-four implant-abutment assemblies with an internal conical-hex connection were divided into two groups: Stock abutments (SA) and custom abutments (CA).

View Article and Find Full Text PDF

Introduction: Odanacatib (ODN), a cathepsin K inhibitor, is a drug that reduces bone resorption while preserving bone formation. ODN was initially developed for the treatment of postmenopausal osteoporosis, but further development as a systemic medication has been discontinued. Here, we propose ODN as a topical treatment, the coating of dental implants, to achieve an anabolic shift of early osseointegration.

View Article and Find Full Text PDF

Study Design: Cross-sectional study.

Objective: This study aimed to analyze the failure patterns of expandable corpectomy cages.

Summary Of Background Data: Expandable corpectomy cages offer significant advantages for anterior column reconstruction but introduce unique mechanical complexities.

View Article and Find Full Text PDF