Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Consumer "Smartbands" can collect physiological parameters, such as heart rate (HR), continuously across the sleep-wake cycle. Nevertheless, the quality of HR data detected by such devices and their place in the research and clinical field is debatable, as they are rarely rigorously validated. The objective of the present study was to investigate the reliability of pulse photoplethysmographic detection by the Fitbit ChargeHR (FBCHR, Fitbit Inc.) in a natural setting of continuous recording across vigilance states. To fulfil this aim, concurrent portable polysomnographic (pPSG) and the Fitbit's photoplethysmographic data were collected from a group of 25 healthy young adults, for ≥12 hr. The pPSG-derived HR was automatically computed and visually verified for each 1-min epoch, while the FBCHR HR measurements were downloaded from the application programming interface provided by the manufacturer. The FBCHR was generally accurate in estimating the HR, with a mean (SD) difference of -0.66 (0.04) beats/min (bpm) versus the pPSG-derived HR reference, and an overall Pearson's correlation coefficient (r) of 0.93 (average per participant r = 0.85 ± 0.11), regardless of vigilance state. The correlation coefficients were larger during all sleep phases (rapid eye movement, r = 0.9662; N1, r = 0.9918; N2, r = 0.9793; N3, r = 0.9849) than in wakefulness (r = 0.8432). Moreover, the correlation coefficient was lower for HRs of >100 bpm (r = 0.374) than for HRs of <100 bpm (r = 0.84). Consistently, Bland-Altman analysis supports the overall higher accuracy in the detection of HR during sleep. The relatively high accuracy of FBCHR pulse rate detection during sleep makes this device suitable for sleep-related research applications in healthy participants, under free-living conditions.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9286609PMC
http://dx.doi.org/10.1111/jsr.13346DOI Listing

Publication Analysis

Top Keywords

heart rate
8
detection fitbit
8
fitbit chargehr
8
correlation coefficient
8
rate detection
4
chargehr validation
4
validation study
4
study versus
4
versus portable
4
portable polysomnography
4

Similar Publications

Clinical evaluation of motion robust reconstruction using deep learning in lung CT.

Phys Eng Sci Med

September 2025

Department of Radiology, Otaru General Hospital, Otaru, Hokkaido, Japan.

In lung CT imaging, motion artifacts caused by cardiac motion and respiration are common. Recently, CLEAR Motion, a deep learning-based reconstruction method that applies motion correction technology, has been developed. This study aims to quantitatively evaluate the clinical usefulness of CLEAR Motion.

View Article and Find Full Text PDF

Objective: To prepare astragaloside IV dripping pills (ASDP) and assess their therapeutic effects on mice with doxorubicin hydrochloride-induced dilated cardiomyopathy (DCM).: Astragaloside IV (AS) exhibits pharmacological effects in treating cardiovascular diseases, however, its clinical application is hindered by poor solubility and low bioavailability. The study sheds light on new therapeutic strategy of DCM and development of AS formulations.

View Article and Find Full Text PDF

Background And Aims: Fulminant myocarditis (FM) is a complex clinical syndrome characterized by acute myocardial inflammation and cardiogenic shock. Evidence on long-term outcomes, mortality risk factors, and targeted treatment options remains limited.

Methods: This retrospective analysis included consecutive adult patients admitted for FM between January 2012 and November 2022 at 26 European tertiary centres.

View Article and Find Full Text PDF

Sepsis remains a leading cause of critical illness and mortality worldwide, driven by a dysregulated host response to infection and often complicated by persistent tachycardia and cardiovascular dysfunction. Increasing evidence implicates excessive sympathetic activation as a contributor to sepsis-related hemodynamic instability and myocardial injury, prompting growing interest in the use of β-adrenergic blockade as a therapeutic adjunct. This review synthesizes current data on the safety and efficacy of short-acting, cardioselective β-blockers (BBs), particularly esmolol and landiolol, in septic shock.

View Article and Find Full Text PDF