A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Direct Analysis from Phase-Separated Liquid Samples using ADE-OPI-MS: Applicability to High-Throughput Screening for Inhibitors of Diacylglycerol Acyltransferase 2. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

The primary goal of high-throughput screening (HTS) is to rapidly survey a broad collection of compounds, numbering from tens of thousands to millions of members, and identify those that modulate the activity of a therapeutic target of interest. For nearly two decades, mass spectrometry has been used as a label-free, direct-detection method for HTS and is widely acknowledged as being less susceptible to interferences than traditional optical techniques. Despite these advantages, the throughput of conventional MS-based platforms like RapidFire or parallel LC-MS, which typically acquire data at speeds of 6-30 s/sample, can still be limiting for large HTS campaigns. To overcome this bottleneck, the field has recently turned to chromatography-free approaches including MALDI-TOF-MS and acoustic droplet ejection-MS, both of which are capable of throughputs of 1 sample/second or faster. In keeping with these advances, we report here on our own characterization of an acoustic droplet ejection, open port interface (ADE-OPI)-MS system as a platform for HTS using the membrane-associated, lipid metabolizing enzyme diacylglycerol acyltransferase 2 (DGAT2) as a model system. We demonstrate for the first time that the platform is capable of ejecting droplets from phase-separated samples, allowing direct coupling of liquid-liquid extraction with OPI-MS analysis. By applying the platform to screen a 6400-member library, we further demonstrate that the ADE-OPI-MS assay is suitable for HTS and also performs comparably to LC-MS, but with an efficiency gain of >20-fold.

Download full-text PDF

Source
http://dx.doi.org/10.1021/acs.analchem.0c04312DOI Listing

Publication Analysis

Top Keywords

high-throughput screening
8
diacylglycerol acyltransferase
8
acoustic droplet
8
hts
5
direct analysis
4
analysis phase-separated
4
phase-separated liquid
4
liquid samples
4
samples ade-opi-ms
4
ade-opi-ms applicability
4

Similar Publications