Background And Purpose: Monte Carlo simulations as well as analytical computations of proton transport in material media require accurate values of multiple Coulomb scattering (MCS) angles. High-quality experimental data on MCS angles in the energy range for proton therapy are, however, sparse. In this work, MCS modeling in proton transport was evaluated employing an experimental method to measure these angles on a medical proton beamline in clinically relevant materials. Results are compared to Monte Carlo simulations and analytical models.

Materials And Methods: Aluminum, brass, and lucite (PMMA) scatterers of clinically relevant thicknesses were irradiated with protons at 100, 160, and 220 MeV. Resulting spatial distributions of individual pencil beams were measured with a scintillating screen. The MCS angles were determined by deconvolution and a virtual point source approach. Results were compared to those obtained with the Monte Carlo codes PENH, TOPAS, and RayStation Monte Carlo, as well as the analytical models RayStation Pencil Beam Algorithm and the Molière/Fano/Hanson variant of the Molière theory.

Results: Experimental data obtained with the presented methodology agree with previously published results within 6%, with an average deviation of 3%. The combined average uncertainty of the experimental data yielded 1.8%, while the combined maximum uncertainty was below 4%. The obtained Monte Carlo results for PENH, TOPAS, and RayStation deviate on average for all considered energies, materials and thicknesses, by 2.5%, 3.4%, and 2.8% from the experimental data, respectively. For the analytical models, the average deviations amount to 4.5% and 2.9% for the RayStation Pencil Beam Algorithm and the Molière/Fano/Hanson model, respectively.

Conclusion: The experimental method developed for the present work allowed to measure MCS angles in clinical proton facilities with good accuracy. The presented method permits to extend the database on experimental MCS angles which is rather limited. This work further provides benchmark data for lucite in thicknesses relevant for clinical applications. The data may serve to validate dose engines of treatment planning systems and secondary dose check software. The Monte Carlo and analytical algorithms studied are capable of reproducing MCS data within the required accuracy for clinical applications.

Download full-text PDF

Source
http://dx.doi.org/10.1002/mp.14860DOI Listing

Publication Analysis

Top Keywords

monte carlo
28
mcs angles
20
experimental data
16
carlo simulations
12
multiple coulomb
8
coulomb scattering
8
well analytical
8
proton transport
8
experimental method
8
clinically relevant
8

Similar Publications

Chemical alteration of UO micro-particles in model lung systems.

J Hazard Mater

August 2025

Radiochemistry Unit, Department of Chemistry, The University of Helsinki, Helsinki 00560, Finland. Electronic address:

Uranium dioxide (UO) particles can be released from mines, nuclear fuel manufacturing, reactor accidents, and weapons use. They pose inhalation risks, yet their behavior in the human lung remains poorly understood. This study investigates the long-term chemical alteration and dissolution of µm-sized UO particles in two model lung fluids: Simulated Lung Fluid (SLF) and Artificial Lysosomal Fluid (ALF), representing extracellular and intracellular lung environments, respectively.

View Article and Find Full Text PDF

Pb-210 in volume samples: self-attenuation and scattering problems.

Appl Radiat Isot

September 2025

Horia Hulubei National Institute for R&D in Physics and Nuclear Engineering (IFIN-HH), 30 Reactorului Str., PO Box MG-6, Magurele, Ilfov County, RO-077125, Romania. Electronic address:

In this work we study the effect of the matrix of the source on the spectrum and on the full energy peak efficiency for low energy photons. Using realistic simulations carried out with PENELOPE 2018, including detector resolution, we show that small angle Compton scattering does contribute to the peak count rate, implying the dependence of the matrix effects on the linear attenuation coefficient μ and also on the scattering cross section. We show that the effect of Compton scattering can be removed from the apparent peak, resulting a "clean" peak depending only on μ.

View Article and Find Full Text PDF

Coarsening and degradation phenomena in metals have largely focused on thermally driven processes, such as bulk and surface diffusion. However, dramatic coarsening has been reported in high-surface-area, nanometer-sized Pt-based catalysts during potential cycling in an electrolyte at room temperature─a temperature too low for the process to be explained purely by surface mobility values measured in both vacuum and electrolytes (∼10 and ∼10 cm/s, respectively). This morphological evolution must be due to a different mechanism for mass transport that is sensitive to electrochemical conditions (e.

View Article and Find Full Text PDF

Modeling within-level latent interaction effects in multilevel vector-autoregressive models.

Behav Res Methods

September 2025

Wilhelm-Wundt Institute for Psychology, Leipzig University, Neumarkt 9-19, 04109, Leipzig, Germany.

The study of time-dependent within-person dynamics has gained popularity in recent years through the use of multilevel (latent) time-series models. However, due to the complexity of the models, model applications are usually limited with respect to the inclusion of time-varying moderating factors on the longitudinal within-person relations between variables. That is, in common applications of multilevel time-series models, the within-person dynamics of constructs over time are regarded as being insensitive to changes in other time-varying factors or changes in contexts.

View Article and Find Full Text PDF

Introduction: The accuracy of dose delivery in radiotherapy is paramount to maximize tumor control while minimizing damage to surrounding healthy tissues. This study presents a comprehensive analysis of gamma index validation in the treatment of cancerous tumors using Monte Carlo simulations with GAMOS and GATE codes on a Varian medical linear accelerator. By leveraging the MC method's robust statistical capabilities, the precision of dose distributions in external radiotherapy is aimed to be enhanced.

View Article and Find Full Text PDF