A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Non-uniformity calibration method of space-borne area CCD for directional polarimetric camera. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

The directional polarimetric camera (DPC) is a polarization sensor with the characteristics of ultra-wide-angle and low-distortion imaging. The multi-angle polarization information is helpful to obtain the spatial distribution of target radiation, and multiple data fusion relies on the non-uniformity calibration of image plane. The non-uniformity consists of many factors such as lens, detector assembly, spatial stray light, etc. The single correction method can not distinguish the error source effectively. In consideration of the in-flight operation mode of DPC based on the adjustment of exposure time, the non-uniformity correction method of the detector based on multi parameters is proposed. Through the electro-optical performance measurement system of the CCD detector, the sensitive factors such as temperature, dark current, exposure time and spectral response are obtained. After a series of preprocessing of the image including removal of dark signal, removal of smearing effect and temperature compensation, the non-uniformity calibration based on multi-parameters is imposed on the detector. The low-frequency unbalanced response difference of the image surface is eliminated, and the high-frequency difference is effectively suppressed. The experimental results show that the photo response non-uniformity of 95% full well single frame data is reduced from 2.86% to 0.36%. After correction, the data noise is shown as shot noise, and the detector has good ability of dynamic range adjustment. The non-uniformity calibration by the proposed method can offer data support for the instrumental calibration and in-flight fast calculation, and provide effective reference for the subsequent polarization remote sensing instruments.

Download full-text PDF

Source
http://dx.doi.org/10.1364/OE.410768DOI Listing

Publication Analysis

Top Keywords

non-uniformity calibration
16
directional polarimetric
8
polarimetric camera
8
correction method
8
exposure time
8
non-uniformity
7
detector
5
method
4
calibration method
4
method space-borne
4

Similar Publications