A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

A new device to treat mitral valve regurgitation: a proof of concept in bench test study. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Mitral valve repair is typically performed by implanting a ring-like device at the valve annulus to reshape the annulus and to improve leaflet coaptation. In most cases, some additional procedures are needed, including leaflet resection and artificial chordae implantation. However, artificial chordae implantation could be technically challenging and postoperative left ventricular remodeling could increase the risk of recurrent mitral regurgitation. We propose an innovative annular device made of chromo-cobalt, finalized not only to reshape the annulus but also to enable anchoring of leaflets to a fixed intraventricular structure. Durability evaluation of the device was tested by applying eight radial force vectors equally spaced along the ring and related fatigue analysis. To evaluate the efficacy of the mitral valvuloplasty using the tested ring, the device was implanted in five adult swine hearts. Functional analysis of the ring was performed by measuring left ventricular pressure and fluid volume loss, following implantation in normal and dysfunctional mitral valve leaflets. Both fatigue and functional analysis showed satisfactory and promising results in terms of durability and efficacy of mitral valve repair. Because of its favorable durability and functional characteristics this device appears promising and provides good results in terms of valve competence, thus avoiding both manipulations of papillary muscles and interference in left ventricular hemodynamics. However, an test is mandatory to fully understand the impact of the device on subvalvular apparatus.

Download full-text PDF

Source
http://dx.doi.org/10.1080/03091902.2021.1891312DOI Listing

Publication Analysis

Top Keywords

mitral valve
16
left ventricular
12
valve repair
8
reshape annulus
8
artificial chordae
8
chordae implantation
8
efficacy mitral
8
functional analysis
8
device
7
mitral
6

Similar Publications