A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Localization of myocardial infarction with multi-lead ECG based on DenseNet. | LitMetric

Localization of myocardial infarction with multi-lead ECG based on DenseNet.

Comput Methods Programs Biomed

Key Laboratory of Digital Medical Engineering of Hebei Province, Baoding 071000, China; College of Electronic and Information Engineering, Hebei University, Baoding 071002, China. Electronic address:

Published: May 2021


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background And Objective: Myocardial infarction (MI) is a critical acute ischemic heart disease, which can be early diagnosed by electrocardiogram (ECG). However, the most research of MI localization pay more attention on the specific changes in every ECG lead independent. In our study, the research envisages the development of a novel multi-lead MI localization approach based on the densely connected convolutional network (DenseNet).

Methods: Considering the correlation of the multi-lead ECG, the method using parallel 12-lead ECG, systematically exploited the correlation of the inter-lead signals. In addition, the dense connection of DenseNet enhanced the reuse of the feature information between the inter-lead and intra-lead signals. The proposed method automatically captured the effective pathological features, which improved the identification of MI.

Results: The experimental results based on PTB diagnostic ECG database showed that the accuracy, sensitivity and specificity of the proposed method was 99.87%, 99.84% and 99.98% for 11 types of MI localization.

Conclusions: The proposed method has achieved superior results compared to other localization methods, which can be introduced into the clinical practice to assist the diagnosis of MI.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.cmpb.2021.106024DOI Listing

Publication Analysis

Top Keywords

proposed method
12
myocardial infarction
8
multi-lead ecg
8
ecg
6
localization
4
localization myocardial
4
infarction multi-lead
4
ecg based
4
based densenet
4
densenet background
4

Similar Publications