Article Abstract

Background: The purpose of this work was to evaluate orthopedic surgeons' exposure to occupational radiation doses from scattering using a mobile flat panel C-arm X-ray machine at different standing positions during an intraoperative pedicle screw implantation.

Objective: Evaluate the radiation dose received by medical staff, by applying flat X-ray machine in surgical room during an intraoperative pedicle screw implantation.

Methods: A mobile flat-panel C-arm X-ray machine at a dedicated orthopedic operating room was used to image an anthropomorphic female phantom which was set in a prone position on the operating table. The X-ray was projected horizontally, and 1 minute continuous fluoroscopy was used for lumbar spine and thoracolumbar spine during pedicle screw implantation. Scattering radiation doses to orthopedic surgeons were measured at different standing positions and body heights (50, 100, 150 cm above the ground) with and without limited collimations.

Results: The dose area product (DAP) in this experiment is normalized as 343 μGy⋅m2. In the four areas, the lowest scattered radiation measured by DF is 11.2 vs. 0.7 μSv, outside and inside the lead suit, respectively, with or without restricted field, 150 cm above the ground, and the lowest scattered radiation dose inside the lead suit. It is 1.3 vs. 0.5 μSv. Comparing the highest dose of the TF at with the lowest dose of the DF, the average result is 73.7 vs. 11.1 μSv, P< 0.05.

Conclusions: Using a mobile flat-panel C-arm X-ray machine during a pedicle screw implantation, the minimum scattering radiation to surgeons was found to be at the terminal DF area based on the analysis of the scattering doses orthopedic surgeons were exposed to.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8150624PMC
http://dx.doi.org/10.3233/THC-218021DOI Listing

Publication Analysis

Top Keywords

pedicle screw
20
x-ray machine
16
c-arm x-ray
12
occupational radiation
8
radiation doses
8
standing positions
8
intraoperative pedicle
8
radiation dose
8
mobile flat-panel
8
flat-panel c-arm
8

Similar Publications

Posterior lumbar screw fixation is the most common surgical method for lumbar disc herniation, but patients often face multiple complications postoperatively. The occurrence of screw track loosening can lead to fusion failure and even life-threatening screw track extrusion. However, there is currently a lack of animal models specifically targeting changes in the screw track following lumbar screw fixation.

View Article and Find Full Text PDF

Thoracic aortic injury as a complication of spinal surgery: A new case and systematic review (1991-2024).

J Vasc Surg Cases Innov Tech

December 2025

Faculdade de Ciências Médicas de Alagoas, Vascular and Endovascular Surgery Division, Alagoas, Alagoas, Brazil.

Background: Iatrogenic thoracic aortic injury (TAI) is a rare but well-recognized complication of spine surgery, lacking standardized treatment guidelines due to its rarity and variability of manifestations.

Methods: We present a new case of TAI successfully managed with endovascular repair and systematically reviewed 52 articles (1991-2024) reporting 64 cases, including demographics, surgical indications, injury patterns, and treatments.

Results: A 53-year-old man with a T7 fracture underwent posterior spinal instrumentation and developed chest pain due to a combination of impingement and screw penetration into the thoracic aorta and was treated with thoracic endovascular aortic repair (TEVAR) and removal of pedicle screws.

View Article and Find Full Text PDF

Background: The lateral transpsoas lumbar interbody fusion is associated with transient postoperative anterior thigh and inguinal dysesthesias and hip flexor weakness from manipulation of the psoas and interposed lumbar plexus. However, it remains unclear whether this translates to higher pain scores and opioid requirements.

Methods: Patients who had undergone one- or two-level extreme/direct (XLIF/DLIF), anterior (ALIF), or transforaminal lumbar interbody fusion (TLIF) between January 2018 and December 2023 for degenerative spinal pathology were included.

View Article and Find Full Text PDF

Purpose We aimed to compare postoperative changes in intervertebral foraminal areas and the mechanisms of foraminal stenosis following fixation surgery for cervical spondylotic myelopathy (CSM) with local kyphosis and instability, using three-dimensional computed tomography (3DCT). Methods We retrospectively analyzed 55 patients who underwent posterior cervical spinal fixation using pedicle screws. A total of 71 spinal levels (C2/3 to C7/T1) and 144 intervertebral foramina with anchor screws inserted in the upper and lower vertebrae were examined.

View Article and Find Full Text PDF

Background: Posterior lumbar fusion (PLF) has become one of the most common spinal surgery procedures. Early symptomatic loosening of the pedicle screw could be a critical complication, leading to pseudarthrosis. However, revision strategies for pedicle screw loosening are still under debate.

View Article and Find Full Text PDF