A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Microwave-based strategies for sample preparation and halogen determination in blood using ICP-MS. | LitMetric

Microwave-based strategies for sample preparation and halogen determination in blood using ICP-MS.

Talanta

Departamento de Química, Universidade Federal de Santa Maria, 97105-900, Santa Maria, RS, Brazil. Electronic address:

Published: May 2021


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

In this work, two microwave-assisted sample preparation methods based on combustion and ultraviolet digestion for futher determination of Br, Cl, and I in blood by inductively coupled plasma mass spectrometry were proposed. For microwave-induced combustion (MIC), blood was spotted on square pieces of Munktell TFN paper, and water and diluted NHOH were evaluated as absorbing solutions. The stability of the analytes in the spotted blood was also evaluated. During 90 days, no changes of halogen content were observed for samples (with and without anticoagulant) on paper stored in a desiccator at 20 ± 5 °C. Whole blood was also digested by microwave-assisted ultraviolet digestion (MAD-UV). Some parameters as the volume of HNO solution, the influence of HO, and the effect of UV radiation were investigated. The interferences caused by C and K on halogen determination were carefully investigated. The results for MIC and MAD-UV and Br, Cl and I determination by ICP-MS presented no difference. The accuracy of MIC and MAD-UV was also evaluated by analyte spike with reference solutions of Br, Cl and I using inorganic species and also organic I standard (T4-levothyroxine). For both methods, recoveries were 94 and 108% for Br, 96 and 103% for Cl, and 104 and 97% for I. In case of organic I, recoveries were 99 and 111% for MIC and MAD-UV, respectively. The limits of quantification for MIC and MAD-UV after ICP-MS determination were 0.06 and 0.04 μg g for Br, 14 and 30 μg g for Cl and 12 and 8 ng g for I, respectively. The proposed methods provide a suitable digestion approach, assuring safety and high digestion efficiency for further halogen determination in blood, with the possibility to use in clinical analysis.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.talanta.2021.122157DOI Listing

Publication Analysis

Top Keywords

mic mad-uv
16
halogen determination
12
determination blood
12
sample preparation
8
ultraviolet digestion
8
determination
6
blood
6
mic
5
mad-uv
5
microwave-based strategies
4

Similar Publications