Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 317
Function: require_once
98%
921
2 minutes
20
The sacroiliac joint (SIJ) is a known pain generator that, in severe cases, may require surgical fixation to reduce intra-articular displacements and allow for arthrodesis. The objective of this computational study was to analyze how the number of implants affected SIJ stabilization with patient-specific characteristics such as the pelvic geometry and bone quality. Detailed finite element models were developed to account for three pelvises of differing anatomy. Each model was tested with a normal and low bone density (LD) under two types of loading: compression only and compression with flexion and extension moments. These models were instrumented with one to three cylindrical, threaded and fenestrated implants through a posterior oblique trajectory, requiring less muscle dissection than the more common lateral trajectory used with triangular implants. Compared with the noninstrumented pelvis, the change in range of motion (ROM) and stress distribution were used to characterize joint stabilization. Noninstrumented mobility ranged from 0.86 to 2.55 mm and from 1.37° to 6.11°. Across patient-specific characteristics, the ROM reduction with one implant varied from 3% to 21% for vertical and 15% to 47% for angular displacements. With two implants, the ROM reduction ranged from 12% to 41% for vertical and from 28% to 61% for angular displacements. Three implants, however, did not further improve the joint stability (14% to 42% for vertical and 32% to 63% for angular displacements). With respect to patient characteristics, an LD led to a decreased stabilization and a higher volume of stressed bone (>75% of yield stress). A better understanding of how patient characteristics affect the implant performance could help improve surgical planning of sacroiliac arthrodesis.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/jor.25012 | DOI Listing |