A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Use of a simple empirical model for the accurate conversion of the seawater pH value measured with NIST calibration into seawater pH scales. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

The seawater pH measurement is usually quite complicated because that matrix is characterized by a high ionic strength leading to calibration errors if NIST standards are used. For this matrix, different pH scales like the "total hydrogen ion concentration scale" (TOT) and the "seawater scale" (SWS), are defined, and suitable synthetic seawater solutions must be prepared according to standard procedures to calibrate the glass electrode. This work provides a new approach to make seawater pH measurements by using the glass electrode calibrated with the NIST standards (pH) converting the pH into the right TOT or SWS scales by using empirical equations derived from theoretical thermodynamic data: pH=pH+0.10383+4.33⋅10TS+3.633⋅10T-4.921⋅10S, and pH=pH+0.097733+4.1059⋅10TS+3.5437⋅10T-4.941⋅10S, for the TOT and SWS scales, respectively. These equations are functions of two simple experimental parameters, namely, T = temperature (°C) and S = salinity (PSU, (g/L), Practical Salinity Units). These equations were experimentally validated and the uncertainty of pH and pH was demonstrated to have no statistical difference with the corresponding values obtained following the standard operative procedure (SOP) using commercially unavailable seawater-like buffers. The proposed method has therefore the same performances and it is largely preferable as it avoids long and tedious procedures of the synthetic seawater preparations.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.talanta.2020.122051DOI Listing

Publication Analysis

Top Keywords

nist standards
8
synthetic seawater
8
glass electrode
8
tot sws
8
sws scales
8
seawater
6
simple empirical
4
empirical model
4
model accurate
4
accurate conversion
4

Similar Publications