A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Cultivation of with Feedback Regulation of Glucose Concentration Controlled by Optical Fiber Glucose Sensor. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Glucose belongs among the most important substances in both physiology and industry. Current food and biotechnology praxis emphasizes its on-line continuous monitoring and regulation. These provoke increasing demand for systems, which enable fast detection and regulation of deviations from desired glucose concentration. We demonstrated control of glucose concentration by feedback regulation equipped with in situ optical fiber glucose sensor. The sensitive layer of the sensor comprises oxygen-dependent ruthenium complex and preimmobilized glucose oxidase both entrapped in organic-inorganic polymer ORMOCER. The sensor was placed in the laboratory bioreactor (volume 5 L) to demonstrate both regulations: the control of low levels of glucose concentrations (0.4 and 0.1 mM) and maintenance of the glucose concentration (between 2 and 3.5 mM) during stationary phase of cultivation of . Response times did not exceed 6 min (average 4 min) with average deviation of 4%. Due to these regulation characteristics together with durable and long-lasting (≥2 month) sensitive layer, this feedback regulation system might find applications in various biotechnological processes such as production of low glucose content beverages.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7830682PMC
http://dx.doi.org/10.3390/s21020565DOI Listing

Publication Analysis

Top Keywords

glucose concentration
16
feedback regulation
12
glucose
10
optical fiber
8
fiber glucose
8
glucose sensor
8
sensitive layer
8
min average
8
regulation
6
cultivation feedback
4

Similar Publications