Article Abstract

Introduction: Pericardiocentesis is a potentially life-saving procedure. We compared two low-cost models-an agar-based model and a novel model, Centesys-in terms of ultrasound image quality and realism, effectiveness of the model, and learners' confidence and satisfaction after training.

Methods: In this pilot randomised 2x2 crossover trial stratified by physician seniority, participants were assigned to undergo pericardiocentesis training either with the agar-based or Centesys model first, followed by the other model. Participants were asked to rate their confidence in performing ultrasound-guided pericardiocentesis, clarity and realism of cardiac structures on ultrasound imaging, and satisfaction on a 7-point Likert scale before and after training with each model.

Results: Twenty participants with median postgraduate year of 4 (interquartile range [IQR] 3.75-6) years were recruited. Pre-training, participants rated themselves a median score of 2.5 (IQR 2-4) for level of confidence in performing pericardiocentesis, which improved to 5 (IQR 4-6) post-training with Centesys (=0.007). Centesys was recognised to be more realistic in simulating cardiac anatomy on ultrasound (median 5 [IQR 4-5] versus 3.5 [IQR 3-4], =0.002) than the agar-based model. There was greater satisfaction with Centesys (median 5 [IQR 5-6] versus 4 [IQR 3.75-4], <0.001). All 20 participants achieved successful insertion of a pericardial drain into the simulated pericardial sac with Centesys.

Conclusion: Centesys achieved greater learner satisfaction as compared to the agar-based model, and was an effective tool for teaching ultrasound-guided pericardiocentesis and drain insertion.

Download full-text PDF

Source
http://dx.doi.org/10.47102/annals-acadmedsg.2020266DOI Listing

Publication Analysis

Top Keywords

agar-based model
8
confidence performing
8
median [iqr
8
versus [iqr
8
model
6
pericardiocentesis
5
comparison reusable
4
reusable models
4
models pericardiocentesis
4
pericardiocentesis simulation
4

Similar Publications

This study characterized agar extracted from Gelidium elegans using ultrasound-assisted extraction (UAE) compared with conventional extraction (CV). The CV yielded significantly higher agar (21.50 %) than UAE (17.

View Article and Find Full Text PDF

Real-time, multiplexed monitoring of wound infection biomarkers is essential for early detection of infection and inflammation, as well as for evaluating wound healing progression. However, existing biosensing technologies lack the sensitivity, specificity, and integration needed to meet these clinical demands. To address current limitations in wound monitoring, we developed a portable and multimodal sensor system capable of simultaneously detecting uric acid (UA), phenazine-1-carboxylic acid (PCA), interleukin-6 (IL-6), and pH.

View Article and Find Full Text PDF

Robust and reproducible plant culture systems are essential for studying physiological, molecular, and developmental responses under controlled conditions. In particular, investigating how plants respond to nutrient limitation or abiotic stress requires precise regulation of the growth environment, something that traditional soil- or agar-based systems often fail to provide. Arabidopsis thaliana, the leading model plant species, presents unique challenges in this regard due to its compact size and sensitivity to environmental variability.

View Article and Find Full Text PDF

Significance: Macroscopic Fluorescence Lifetime Imaging (MFLI) is a powerful, non-invasive imaging modality that offers robust, physiologically relevant contrast largely independent of fluorophore concentration, excitation intensity, and tissue signal attenuation. However, accurately determining the depth of signal origin remains challenging, potentially leading to ambiguity in biological interpretation. Here, we present a novel optical correction method that effectively eliminates surface signal bias, such as that from skin in preclinical imaging, without the need for chemical clearance.

View Article and Find Full Text PDF

Contaminated packaging materials may represent a potential risk in food processing environments, particularly when no prior treatment is applied. This study aimed to develop a quantitative method to classify the fungal biodeterioration of lignocellulosic materials commonly used in food-related applications. Six lignocellulosic supports were evaluated: coated cardboard, uncoated cardboard, corrugated cardboard, kraft paper, cupcake wrapper, and Waltman No.

View Article and Find Full Text PDF