Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 317
Function: require_once
98%
921
2 minutes
20
Improved settleability has become an essential feature of new wastewater treatment innovations. To accelerate adoption of such new technologies, improved clarifier models are needed to help with designing and predicting improvement in settleability. In general, the level of mathematics of settling clarifier models has gone far beyond the level of existing experimental methods available to support these models. To date, even for simple one-dimensional (1D) clarifier models, no experimental method has been described for flocculent settling coefficient (r). As a consequence, r cannot be considered as a sludge characteristic and is used as a calibration parameter to achieve observed effluent quality. In this study, we focused on the development of an empirical function based on a simple and practical experimental approach for the calculation of the r value from sludge characteristics. This approach provided a similar approach as currently taken for hindered settling coefficient calculations (Veslind equation) and allowed for the model to predict effluent quality, thus increasing the power of the 1D model. The threshold of flocculation (TOF), which describes the collision efficiency of particles, directly correlated with the effluent quality of the five tested activated sludge systems and was selected as experimental method. The proposed empirical function between TOF and r was validated for four years of validating data with five different sludge types operated under different operational conditions and configurations. The good effluent quality prediction with this approach brings us one step closer in making the clarification models more predictive towards effluent quality and clarifier performance.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.watres.2020.116294 | DOI Listing |