Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Capillary systems are a promising technology for point-of-care microfluidics, since they are pre-programmable and self-powered. This work introduces "off valves" as a key building block for capillaric circuits, providing easy-to-use, multi-purpose valving functionality and autonomous flow control. To this end we present a set of switching valve designs that use trigger channels and liquid input alone to close or open connections between channels in a highly controllable fashion. The key element of all these valve designs is a new off trigger valve, which is characterised in detail here and holds the potential for transistor-like switching and resistance tuning. As an example for the potential applications of switching valves, we demonstrate how they can be used for flow resistance control in a complex microfluidic circuit and for sequential chemical loading into a reaction chamber. Use of the switching valves for the latter in particular allowed for the tuning of incubation times and volumetric measurement, thus confirming applicability of the valves for automated and self-powered immunoassays in point-of-care environments.

Download full-text PDF

Source
http://dx.doi.org/10.1039/d0lc00811gDOI Listing

Publication Analysis

Top Keywords

flow control
8
valve designs
8
designs trigger
8
switching valves
8
control systems
4
systems capillarics
4
valves
4
capillarics valves
4
valves capillary
4
capillary systems
4

Similar Publications

Observing differential spin currents by resonant inelastic X-ray scattering.

Nature

September 2025

National Synchrotron Light Source II, Brookhaven National Laboratory, Upton, NY, USA.

Controlling spin currents, that is, the flow of spin angular momentum, in small magnetic devices, is the principal objective of spin electronics, a main contender for future energy-efficient information technologies. A pure spin current has never been measured directly because the associated electric stray fields and/or shifts in the non-equilibrium spin-dependent distribution functions are too small for conventional experimental detection methods optimized for charge transport. Here we report that resonant inelastic X-ray scattering (RIXS) can bridge this gap by measuring the spin current carried by magnons-the quanta of the spin wave excitations of the magnetic order-in the presence of temperature gradients across a magnetic insulator.

View Article and Find Full Text PDF

The present investigation sought to determine the cardiovascular responses to a commercially available KAATSU cuff system with rhythmic cuff inflation-deflation periods during leg exercise. Seventeen participants performed two-legged knee flexion/extension exercise at 25% of peak work rate (WR) with bilateral KAATSU cuffs applied to the proximal thigh (KAATSU) or work-rate matched control exercise (CTL). During KAATSU trials, the cuffs were set to Cycle Mode (repeated 30-s inflation; 5-s deflation) at progressively increasing cuff pressure (150-220 mmHg).

View Article and Find Full Text PDF

Among the different forms of hydrotherapy, carbon dioxide (CO) water immersion improves peripheral vasodilation and blood flow compared with tap water immersion; however, the heat stress placed on the body through CO water immersion and the appropriate immersion protocols are uncertain. Therefore, this study aimed to compare the thermoregulatory responses during CO and tap water immersions. The participants were 10 male college baseball players.

View Article and Find Full Text PDF

Aims: In-stent restenosis (ISR) is a significant limitation of coronary stent implantation, but the exact mechanism of ISR remains unclear. Patients after percutaneous coronary intervention (PCI) are in a hypercoagulable state; however, there is less information on its association with chronic coronary artery disease (CAD) in patients with ISR after PCI. We aimed to clarify whether or not CAD patients with ISR after PCI are in a hypercoagulable state and whether or not PS exposure on extracellular vesicles (EVs), blood cells (BCs), and endothelial cells (ECs) is involved in the hypercoagulable state.

View Article and Find Full Text PDF

Systematic review of pedestrian safety at roundabouts.

J Safety Res

September 2025

Department of Civil Engineering, Kırıkkale University, 71450 Yahşihan, Kırıkkale, Turkiye. Electronic address:

Introduction: Roundabouts are increasingly being used to improve traffic flow and reduce conflict points compared to traditional intersections. While previous studies have generally shown that roundabouts reduce vehicle collisions and improve traffic conditions, their impact on pedestrian safety, particularly in urban areas with high pedestrian traffic, has not been adequately studied. Despite the potential of roundabouts to reduce the overall severity of collisions, recent studies also point to specific safety challenges for pedestrians, including the difficulties faced by slow-moving people, changes in pedestrian behavior when avoiding roundabouts, and problems with disabled pedestrians are faced with.

View Article and Find Full Text PDF