Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Soil microplastic pollution has caused widespread research attention worldwide. It is necessary to efficiently separate microplastic particles from soil matrixes in order to conduct studies of microplastic. And so far, few studies have described the separation and extraction devices of biodegradable microplastic. Here we present a commonly available device for extraction of non-degradable and biodegradable microplastics from soil samples in a NaBr solution based on density flotation. The device has a combined circulation and recovery system for the salt solution, which increases its environmental-friendliness. The accuracy and precision of the device was verified through spike and recovery experiments using three types of biodegradable microplastics (PBS, PBAT, PLA) and four types of non-degradable microplastics (LDPE, PS, PP, PVC), all with different particle sizes, and all microplastics are grinded autonomously, closer to reality. In despite of differences in particle size and density, for both biodegradable and non-degradable microplastics the device exhibited good extraction precision, with recovery rates ranging from 92% to 99.6%, over a wide range of particle densities and sizes. The recovery rates slightly increased with increased polymer density and microplastic particle size.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.scitotenv.2020.143482DOI Listing

Publication Analysis

Top Keywords

device extraction
8
microplastics soil
8
nabr solution
8
biodegradable microplastics
8
non-degradable microplastics
8
particle size
8
recovery rates
8
microplastics
6
device
5
microplastic
5

Similar Publications

A compact cassette tape for DNA-based data storage.

Sci Adv

September 2025

Shenzhen Key Laboratory of Smart Healthcare Engineering, Guangdong Provincial Key Laboratory of Advanced Biomaterials, Department of Biomedical Engineering. Southern University of Science and Technology, No. 1088 Xueyuan Rd., Nanshan District, Shenzhen, Guangdong 518055, P. R. China.

DNA with high storage density can serve as an alternative storage medium to respond to the global explosion of data growth and become a powerful personal storage memory if an integrated compact device can store and handle large-scale data. Here, we incorporate a DNA cassette tape with 5.5 × 10 addressable data partitions (addressing rate up to 1570 partitions per second), a DNA loading capacity of 28.

View Article and Find Full Text PDF

Wafer-scale integration of monolayer MoS residue-free support layer etching and angular strain suppression.

Nanoscale

September 2025

Institute of Materials Research and Engineering (IMRE), Agency for Science, Technology and Research (A*STAR), 2 Fusionopolis Way, Innovis #08-03, Singapore 138634, Republic of Singapore.

A crack-free and residue-free transfer technique for large-area, atomically-thin 2D transition metal dichalcogenides (TMDCs) such as MoS and WS is critical for their integration into next-generation electronic devices, either as channel materials replacing silicon or as back-end-of-line (BEOL) components in 3D-integrated nano-systems on CMOS platforms. However, cracks are frequently observed during the debonding of TMDCs from their growth substrates, and polymer or metal residues are often left behind after the removal of adhesive support layers wet etching. These issues stem from excessive angular strain accumulated during debonding and the incomplete removal of support layers due to their low solubility.

View Article and Find Full Text PDF

Aims: Cardiogenic shock remains a significant cause of mortality despite multiple advancements in medical interventions. Veno-arterial extracorporeal membrane oxygenation (VA-ECMO) provides crucial circulatory support but also increases left ventricular (LV) after-load, potentially worsening outcomes. Effective LV unloading strategies can enhance patient survival during VA-ECMO treatment.

View Article and Find Full Text PDF

Laparoscopic cryptorchidectomy in 10 equids using a single incision laparoscopic surgery (SILS) port device.

Can Vet J

September 2025

Department of Clinical Studies, Ontario Veterinary College, University of Guelph, 50 Stone Road East, Guelph, Ontario N1G 2W1.

Minimally invasive laparoscopic surgical techniques are desirable in horses and other equids. A new approach called "modified single incision laparoscopic surgery (SILS) for equine cryptorchidectomy" is described, along with the postoperative outcomes of 10 equids. A SILS Port device (Covidien) was placed a 30- to 40-millimeter incision in combination with 1 or 2 15-millimeter para-inguinal incisions to exteriorize the intra-abdominal testicles.

View Article and Find Full Text PDF

Management of Transvenous Leads in Patients With Iatrogenic Lead Perforation.

J Cardiovasc Electrophysiol

September 2025

Cardiac Electrophysiology Section, Department of Cardiovascular Medicine, Cleveland Clinic, Cleveland, Ohio, USA.

Introduction: Iatrogenic lead perforation is a rare but serious complication of cardiac implantable electronic device (CIED) implantation. Evidence on percutaneous management of subacute or delayed cases remains limited.

Methods: We retrospectively reviewed 38 patients treated for iatrogenic lead perforation between January 2012 and October 2024.

View Article and Find Full Text PDF