98%
921
2 minutes
20
Laser time transfer is of great significance in timing and global time synchronization. However, temperature drift may occur and affect the delay of the electronics system, optic generation and detection system. This paper proposes a post-processing method for the compensation of temperature-induced system delay, which does not require any changes to the hardware setup. The temperature drift and time stability of the whole system are compared with and without compensation. The results show that propagation delay drift as high as 240 ps caused by temperature changes is compensated. The temperature drift coefficient was diminished down to ~0.05 ps/°C from ~20.0 ps/°C. The system precision was promoted to ~2 ps from ~11 ps over a time period of 80,000 s. This method performs significant compensation of single-photon laser time transfer system propagation drift and will to help establish an ultra-stable laser time transfer link in a space application.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7699704 | PMC |
http://dx.doi.org/10.3390/s20226655 | DOI Listing |
Biomater Sci
September 2025
Key Laboratory of Biomaterials and Nanotechnology for Cancer Immunotherapy, The Tianjin Key Laboratory of Biomaterials, Institute of Biomedical Engineering, Peking Union Medical College & Chinese Academy of Medical Sciences, Tianjin, 300192, China.
Various cancer therapeutic strategies have been designed for targeting tumor-associated macrophages (TAMs), but TAM reprogramming-based monotherapy is often clinically hindered, likely due to the lack of a coordinated platform to initiate T cell-mediated immunity. Herein, we fabricated reactive oxygen species (ROS)-responsive human serum albumin (HSA)-based nanoparticles (PEG/IL12-IA NPs) consisting of indocyanine green (ICG), arginine (Arg), and interleukin 12 (IL12). Upon laser irradiation, the nanoparticles were found to be able to dissociate, thus facilitating the release of IL12.
View Article and Find Full Text PDFRev Sci Instrum
September 2025
National Centre for Physics (NCP), Islamabad, Pakistan.
Time-resolved data acquisition is crucial for compositional analysis using Laser-Induced Breakdown Spectroscopy (LIBS). It can be managed by adjusting the delay time and gate width of the spectrometer. This study describes the compositional analysis of molybdenum (Mo) ore utilizing charge coupled device (CCD) and intensified charge-coupled device (ICCD) based LIBS systems.
View Article and Find Full Text PDFJ Vet Intern Med
September 2025
Schwarzman Animal Medical Center, New York, New York, USA.
Background: There are limited studies on cystoscopic-guided laser ablation for treating ectopic ureters in male dogs. Further investigation is needed to assess its safety and efficacy.
Hypothesis/objective: Retrospectively describe long-term outcomes in male dogs treated using cystoscopic-guided laser ablation of ectopic ureters (CLA-EU).
J Anal At Spectrom
September 2025
Department of Environmental Systems Science, ETH Zurich Universitätstrasse 16 8092 Zurich Switzerland.
Plastic pollution in marine environments poses ecological risks, in part because plastic debris can release hazardous substances, such as metal-based additives. While microplastics have received considerable attention as vectors of contaminants, less is known about larger macroplastics and their role in the spatial and temporal redistribution of substances. In this study, pristine, store-bought plastic items and macroplastics recovered from the North Pacific Subtropical Gyre (NPSG) were analysed using Fourier-Transform Infrared Spectroscopy (FTIR) to identify polymer types, and bulk acid digestion followed by Inductively Coupled Plasma Mass Spectrometry (ICP-MS) for total metal quantification.
View Article and Find Full Text PDFJ Appl Clin Med Phys
September 2025
Department of Radiation Oncology, Virginia Commonwealth University, Richmond, Virginia, USA.
Purpose: Real‑time magnetic resonance-guided radiation therapy (MRgRT) integrates MRI with a linear accelerator (Linac) for gating and adaptive radiotherapy, which requires robust image‑quality assurance over a large field of view (FOV). Specialized phantoms capable of accommodating this extensive FOV are therefore essential. This study compares the performance of four commercial MRI phantoms on a 0.
View Article and Find Full Text PDF