Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 317
Function: require_once
98%
921
2 minutes
20
Purpose: To achieve highly accelerated submillimeter resolution -weighted functional MRI at 7T by developing a three-dimensional gradient and spin echo imaging (GRASE) with inner-volume selection and variable flip angles (VFA).
Methods: GRASE imaging has disadvantages in that (a) k-space modulation causes blurring by limiting the number of slices and (b) a VFA scheme results in partial success with substantial SNR loss. In this work, accelerated GRASE with controlled blurring is developed to improve a point spread function (PSF) and temporal signal-to-noise ratio (tSNR) with a large number of slices. To this end, the VFA scheme is designed by minimizing a trade-off between SNR and blurring for functional sensitivity, and a new GRASE-optimized random encoding, which takes into account the complex signal decays of and weightings, is proposed by achieving incoherent aliasing for constrained reconstruction. Numerical and experimental studies were performed to validate the effectiveness of the proposed method over regular and VFA GRASE (R- and V-GRASE).
Results: The proposed method, while achieving 0.8 mm isotropic resolution, functional MRI compared to R- and V-GRASE improves the spatial extent of the excited volume up to 36 slices with 52%-68% full width at half maximum (FWHM) reduction in PSF but approximately 2- to 3-fold mean tSNR improvement, thus resulting in higher BOLD activations.
Conclusions: We successfully demonstrated the feasibility of the proposed method in -weighted functional MRI. The proposed method is especially promising for cortical layer-specific functional MRI.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8855518 | PMC |
http://dx.doi.org/10.1002/mrm.28589 | DOI Listing |