Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

The purpose of this study was to determine patient-reported outcomes, hardware removal rates, as well as conversion to arthroplasty at mid-term follow-up following high tibial osteotomy (HTO) with a modern polyetheretherketone (PEEK) system. All PEEK system-based HTOs performed at a single institution between January 2010 and January 2016 with a minimum of 2 years follow-up were reviewed. Rates of postoperative complications, hardware removal and conversion to arthroplasty were calculated. Patient-reported outcomes including visual analog pain scale (VAS), Tegner activity scale, Lysholm, Knee Injury and Osteoarthritis Outcome Score (KOOS), and 36-Item Short Form Survey (SF-36) were obtained. Forty-seven HTOs in 43 patients (mean age: 37.6 ± 10.8 years; 30 M, 13 F) were followed for a mean of 6.0 ± 1.5 years. A total of four postoperative complications occurred in three patients, resulting in an overall complication rate of 6.4%. Hardware removal occurred in three patients at a mean of 0.73 ± 0.53 years after surgery, with overall survival free of hardware removal of 96% (95% confidence interval [CI]: 85-99) at 1 year, 94% (95% CI: 82-98) at 2 years, and 94% (95% CI: 82-98) at 8 years. Conversion to arthroplasty occurred in three patients at a mean of 3.2 ± 1.0 years after surgery, with mean survival of 100% (95% CI: 94-100) at 1 year, 100% (95% CI: 94-100) at 2 years, and 93% (95% CI: 81-98) at 8 years. VAS at rest improved, from 3.1 ± 2.5 preoperatively to 1.1 ± 1.6 postoperatively ( < 0.001). Patients remained active, with a mean Tegner activity scale of 4.4 ± 1.4 at final follow-up and satisfactory Lysholm, KOOS, and SF-36 scores. At mid-term follow-up, medial opening-wedge HTO using a modern PEEK-based system was found to be safe, efficacious, and durable, with satisfactory outcome scores and a low rate of conversion to arthroplasty. PEEK-based implants were found to have low hardware removal rates of 6% at 5 years, which compares favorably to historic metal fixation. This is a Level III study.

Download full-text PDF

Source
http://dx.doi.org/10.1055/s-0040-1721090DOI Listing

Publication Analysis

Top Keywords

hardware removal
16
conversion arthroplasty
12
occurred three
12
three patients
12
years
10
high tibial
8
tibial osteotomy
8
modern polyetheretherketone
8
polyetheretherketone peek
8
peek system
8

Similar Publications

Background: Umbilical arterial catheterisation is a common intervention performed in the neonatal intensive care unit (NICU) especially in extremely preterm and extremely low birth weight neonates. Rarely catheter fracture or breakage can occur, leaving behind part of the catheter in the aorta. A handful of cases have been reported in the literature, with the majority being managed surgically.

View Article and Find Full Text PDF

Background: Evidence supporting surgery in elderly patients with distal radius fractures is limited, but displaced fractures may benefit from surgery. This study aimed to determine whether casting is noninferior to surgery for patients aged 65 years or older with substantially displaced intra-articular (AO type C) distal radius fractures.

Methods: This multicenter randomized controlled noninferiority trial included 138 patients (mean age 76 years, SD 6.

View Article and Find Full Text PDF

Higher precision and preservation of frontal plane alignment in slope-reducing infra-tubercle compared to retro-tubercle high tibial osteotomy.

Knee Surg Sports Traumatol Arthrosc

September 2025

Department of Orthopedic Surgery, APHM, CNRS, ISM, Institute of Movement Sciences, Sainte-Marguerite Hospital, Aix Marseille University, Marseille, France.

Purpose: Slope-reducing high tibial osteotomies (SR-HTOs) correct posterior tibial slope (PTS) abnormalities in patients with anterior knee instability, as in cases of anterior cruciate ligament (ACL) deficiency. The SR-HTO techniques, including infra-tubercle and retro-tubercle approaches, provide distinct benefits: retro-tubercle techniques help preserve patellofemoral joint mechanics, while infra-tubercle techniques are effective in mitigating iatrogenic varus. However, there is limited comparative literature available.

View Article and Find Full Text PDF

Multi-site neuroimaging studies have become increasingly common in order to generate larger samples of reproducible data to answer questions associated with smaller effect sizes. The data harmonization model NeuroCombat has been shown to remove site effects introduced by differences in site-related technical variance while maintaining group differences, yet its effect on improving statistical power in pre-clinical models of CNS disease is unclear. The present study examined fractional anisotropy data computed from diffusion weighted imaging data at 3 and 30 days post-controlled cortical impact injury from 184 adult rats across four sites as part of the Translational-Outcome-Project-in-Neurotrauma (TOP-NT) Consortium.

View Article and Find Full Text PDF

Calcium phosphate bone paste (CPBP) is widely used in cranioplasty, yet its strength under extreme stress and optimal management of subsequent post-traumatic fragmentation remain poorly defined. The aim of this paper is to illustrate the limitations of CPBP durability through a case in which even seemingly hardened material underwent micro-fragmentation due to high-energy trauma after cranioplasty, and to explore the necessity of surgical intervention in such cases. We present a case of a woman in her 30s with multiple complex comorbidities, including immunodeficiency requiring steroid therapy, a fibrinogenolytic system disorder, and fluid management difficulties necessitating diuretics due to protein-losing enteropathy.

View Article and Find Full Text PDF