Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 317
Function: require_once
98%
921
2 minutes
20
Objectives: This study was conducted to assess the impact of tube voltage on ambient dose during intraoral radiography, specifically remnant-beam transmission and scattered radiation.
Methods And Materials: Remnant-beam and scattered radiation doses were recorded using a phantom at tube voltages of 60, 63, 66 and 70 kV. Mathematical equations depicting their relations were then formulated, and reference values were calculated at the various voltages tested. Total ambient doses per exposure at 60 kV and at 70 kV were compared.
Results: Both remnant-beam transmission and scattered radiation increased ~40% by increasing tube voltage from 60 kV to 70 kV, and the relation was linear. A remnant beam transmission reference value of 7.5% was established at 70 kV, as well as a conversion factor of 0.035 µSv/mAs at 1 m for scattered radiation at 60 kV. Given longer exposure times at 60 kV, total ambient dose proved higher at 60 kV than at 70 kV.
Conclusion: Higher tube voltage results in higher remnant-beam transmission and more scattered radiation per workload. The relation is linear in the range between 60kV and 70 kV. Remnant-beam transmission at 70 kV is safely assessed at 7.5%. A conversion factor at 60 kV of 0.035 µSv/mAs at 1 m for the scattered radiation dose can be proposed. Total ambient dose per exposure was higher at 60kV than at 70 kV.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8077998 | PMC |
http://dx.doi.org/10.1259/dmfr.20190362 | DOI Listing |