A zero-dimensional predictive model for the pressure drop in the stenotic coronary artery based on its geometric characteristics.

J Biomech

Division of Cardiology, Department of Internal Medicine, University of Ulsan, College of Medicine, Asan Medical Center, Seoul 05505, Republic of Korea.

Published: December 2020


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

The diameter- or area-reduction ratio measured from coronary angiography, commonly used in clinical practice, is not accurate enough to represent the functional significance of the stenosis, i.e., the pressure drop across the stenosis. We propose a new zero-dimensional model for the pressure drop across the stenosis considering its geometric characteristics and flow rate. To identify the geometric parameters affecting the pressure drop, we perform three-dimensional numerical simulations for thirty-three patient-specific coronary stenoses. From these numerical simulations, we show that the pressure drop is mostly determined by the curvature as well as the area-reduction ratio of the stenosis before the minimal luminal area (MLA), but heavily depends on the area-expansion ratio after the MLA due to flow separation. Based on this result, we divide the stenosis into the converging and diverging parts in the present zero-dimensional model. The converging part is segmented into a series of straight and curved pipes with curvatures, and the loss of each pipe is estimated by an empirical relation between the total pressure drop, flow rate, and pipe geometric parameters (length, diameter, and curvature). The loss in the diverging part is predicted by a relation among the total pressure drop, Reynolds number, and area expansion ratio with the coefficients determined by a machine learning method. The pressure drops across the stenoses predicted by the present zero-dimensional model agree very well with those obtained from three-dimensional numerical simulations.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jbiomech.2020.110076DOI Listing

Publication Analysis

Top Keywords

pressure drop
28
zero-dimensional model
12
numerical simulations
12
pressure
8
model pressure
8
geometric characteristics
8
area-reduction ratio
8
drop stenosis
8
flow rate
8
geometric parameters
8

Similar Publications

Total laryngectomy (TLE) results in the permanent separation of the respiratory and digestive tracts, requiring all airway interventions to occur exclusively via a neck stoma. Although airway obstruction in post-laryngectomy patients is uncommon, it can rapidly become fatal without prompt recognition and understanding of the altered anatomy. Here, we report the case of a patient with a recent TLE for squamous cell carcinoma, who presented to a rural Emergency Department (ED) in acute respiratory distress.

View Article and Find Full Text PDF

Triply periodic minimal surfaces have garnered significant interest in the field of biomaterial scaffolds due to their unique structural properties, including a high surface-to-volume (S/V) ratio, tunable permeability, and the potential for enhanced biocompatibility. Bone scaffolds necessitate specific features to effectively support tissue regeneration. This study examines the permeability and active cell proliferation area of advanced Triply Periodic Minimal Surface (TPMS) lattice structures, focusing on a novel lattice design.

View Article and Find Full Text PDF

Purpose: To investigate hand function and eye drop instillation success in adults with and without glaucoma.

Design: Cross-sectional pilot study.

Subjects: Adults aged ≥ 65 years with glaucoma who use eye drops daily and adults aged 65+ without glaucoma who do not regularly use eye drops.

View Article and Find Full Text PDF

Cerebral small-vessel disease (CSVD) is an important risk factor for cognitive impairment, which is a pressing health issue for the aging population worldwide. The complex relationship between vascular factors, such as blood pressure variability (BPV) and arteriosclerosis index (AI), and cognitive dysfunction in patients with CSVD is a hot research topic, and research in this area will help prevent and treat cognitive dysfunction in CSVD. This study aims to investigate the effects of diastolic BPV (DBPV) and AI on cognitive function in patients with CSVD.

View Article and Find Full Text PDF

Introduction: Pressure-based fractional flow reserve (FFR) and flow-based coronary flow reserve (CFR) assess the functional status of coronary artery disease (CAD) during cardiac catheterization. Complex hemodynamics may not be adequately explained by either pressure or flow alone. Consequently, pressure-drop coefficient (CDP, the ratio between pressure-drop across a stenosis and distal dynamic pressure) that combines both pressure and flow measurements has been developed to distinguish between epicardial stenosis (ES) and microvascular disease (MVD).

View Article and Find Full Text PDF