A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Technical Note: Implications of using EGSnrc instead of EGS4 for extracting electron stopping powers from measured energy spectra. | LitMetric

Technical Note: Implications of using EGSnrc instead of EGS4 for extracting electron stopping powers from measured energy spectra.

Med Phys

Ionizing Radiation Standards, Metrology Research Centre, National Research Council Canada, Ottawa, ON, K1A 0R6, Canada.

Published: April 2021


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Purpose: NRC Report PIRS-0626 (https://doi.org/10.4224/40000364) describes how measured electron energy deposition spectra can be used to determine the electronic stopping power. The stopping power is obtained by comparing measured spectra with spectra calculated using Monte Carlo techniques. The stopping powers reported in PIRS-0626 were obtained using the EGS4 Monte Carlo code. Since then, the EGSnrc code has been released which has more accurate electron transport algorithms. We calculate the effect on the measured stopping powers of using EGSnrc instead of EGS4.

Method: The EGS4 spectra calculated in PIRS-0626 were based on primary electron histories. We first show that those spectra, calculated in 1997, are consistent with current EGS4 spectra calculated using histories. EGSnrc spectra are also calculated using histories and these high-precision spectra are compared to extract any energy difference. The energy differences between the spectra are used to estimate the effect on the measured electronic stopping powers.

Results: The energy differences depend on the absorber material, the absorber thickness and the beam energy. The improved electron elastic scattering cross section of EGSnrc accounts for only part of the difference between the two codes. The effect on the extracted stopping power is largest for the lowest electron energies and can be as large as 0.9%. The calculated spectra show differences for lower energies, with the EGSnrc spectra having a larger proportion of low-energy electrons.

Conclusion: The differences introduced by using EGSnrc instead of EGS4 can affect the estimated stopping power by almost 1% in the worst case but generally the effect is much smaller. We report corrections that can be applied to all the stopping power data in PIRS-0626. An experiment to measure the average energy to create an ion pair in air, , using aluminum detectors will provide an interesting test of the aluminum stopping power data as reported in PIRS-0626 and revised by this work.

Download full-text PDF

Source
http://dx.doi.org/10.1002/mp.14567DOI Listing

Publication Analysis

Top Keywords

stopping power
24
spectra calculated
20
stopping powers
12
spectra
12
stopping
10
egsnrc egs4
8
electronic stopping
8
monte carlo
8
reported pirs-0626
8
egs4 spectra
8

Similar Publications