Article Abstract

Fluorescence imaging has seen enduring use in blood flow visualization and is now finding a new range of applications in image-guided surgery. In this paper, we report a translational study of a new fluorescent agent for use in surgery, pHLIP ICG, where ICG (indocyanine green) is a surgical fluorescent dye used widely for imaging blood flow. We studied pHLIP ICG interaction with the cell membrane lipid bilayer, the pharmacology and toxicology in vitro and in vivo (mice and dogs), and the biodistribution and clearance of pHLIP ICG in mice. The pHLIP ICG tumor targeting and imaging efficacy studies were carried out in several murine and human mouse tumor models. Blood vessels were imaged in mice and pigs. Clinical Stryker imaging instruments for endoscopy and open surgery were used in the study. Intravenously administered pHLIP ICG exhibits a multi-hour circulation half-life, offering protracted delineation of vasculature. As it clears from the blood, pHLIP ICG targets tumors and tumor stroma, marking them for surgical removal. pHLIP ICG is non-toxic, marks blood flow for hours after injection, and effectively delineates tumors for improved resection on the day after administration.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7591906PMC
http://dx.doi.org/10.1038/s41598-020-75443-5DOI Listing

Publication Analysis

Top Keywords

phlip icg
32
blood flow
16
phlip
8
icg
8
blood
6
icg delineation
4
delineation tumors
4
tumors blood
4
flow
4
flow fluorescence-guided
4

Similar Publications

Importance: Breast cancer is one of the leading causes of negligence claims in radiology. The objective of this document is to describe the specific main causes of errors in breast imaging and provide European Society of Breast Imaging (EUSOBI) recommendations to try to minimize these.

Observations: Technical failures represent 17% of all mammographic diagnostic negligence claims.

View Article and Find Full Text PDF

Importance: Misdiagnosis in breast imaging can have significant implications for patients, healthcare providers, and the healthcare system as a whole.

Observations: Some of the potential implications of misdiagnosis in breast imaging include delayed diagnosis or false reassurance, which can result in a delay in treatment and potentially a worse prognosis. Misdiagnosis can also lead to unnecessary procedures, which can cause physical discomfort, anxiety, and emotional distress for patients, as well as increased healthcare costs.

View Article and Find Full Text PDF

Calicheamicin is a potent, cell-cycle independent enediyne antibiotic that binds and cleaves DNA. Toxicity has led to its use in a targeted form, as an antibody-drug conjugate approved for the treatment of liquid tumors. We used a reduced calicheamicin to conjugate it to a single cysteine residue at the membrane-inserting end of a pH Low Insertion Peptide (pHLIP) that targets imaging and therapeutic agents to tumors.

View Article and Find Full Text PDF

Shortwave infrared (900-1,700 nm) fluorescence imaging (SWIRFI) has shown significant advantages over visible (400-650 nm) and near-infrared (700-900 nm) fluorescence imaging (reduced autofluorescence, improved contrast, tissue resolution, and depth sensitivity). However, there is a major lag in the clinical translation of preclinical SWIRFI systems and targeted SWIRFI probes. We preclinically show that the pH low-insertion peptide conjugated to indocyanine green (pHLIP ICG), currently in clinical trials, is an excellent candidate for cancer-targeted SWIRFI.

View Article and Find Full Text PDF