Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 317
Function: require_once
98%
921
2 minutes
20
Purpose: To compare the corneal biomechanical parameters between pseudoexfoliation glaucoma (PXG), primary open-angle glaucoma (POAG) and healthy controls using Corvis ST.
Methods: A prospective, cross-sectional study was conducted which included 132 treatment-naïve eyes which underwent Corvis ST. The study cohort comprised of 44 eyes with PXG, 42 eyes with POAG and 46 healthy controls. Corneal biomechanical parameters, which included corneal velocities, length of corneal applanated surface, deformation amplitude (DA), peak distance and radius of curvature, were compared between the groups using analysis of variance models.
Results: The 3 groups were demographically similar. The mean IOP was 15.7 ±3 mmHg in the control group, 21.3 ±5 mmHg in the POAG group and 25.8 ±7 mmHg in the PXG group (p<0.0001). Corneal pachymetry was similar across the 3 groups. Mean DA was significantly lower (p<0.0001) in the PXG group (0.86 ±0.18 mm) compared to the POAG group (0.97 ±0.14mm) and the control group (1.10 ±0.15mm). Corneal velocities were also found to be statistically significantly different between the groups. However, after adjusting for IOP, there was no difference in any of the biomechanical parameters between the 3 groups.
Conclusion: Corneal biomechanical parameters measured on Corvis ST are not different between eyes with PXG, POAG and healthy controls after adjusting for IOP.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7588080 | PMC |
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0241296 | PLOS |