A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Intra- and inter-evaluator reliability of the MyotonPRO for the assessment of the viscoelastic properties of caesarean section scar and unscarred skin. | LitMetric

Intra- and inter-evaluator reliability of the MyotonPRO for the assessment of the viscoelastic properties of caesarean section scar and unscarred skin.

Skin Res Technol

Department of Family Medicine and Emergency Medicine, Faculty of Medicine and Health Sciences, Université de Sherbrooke, Sherbrooke, Quebec, Canada.

Published: May 2021


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: The clinical evaluation of viscoelastic properties of the Caesarean section (C-section) scar, such as stiffness and elasticity, is usually carried out using subjective scales and palpation techniques. There is currently no reliable and valid tool that objectively quantifies these properties. The MyotonPRO could fill this gap.

Materials And Methods: Nineteen healthy women aged between 21 and 40 years with C-section scars participated in this reliability study. Two points, one on the scar and one on unscarred skin, were measured four times successively with the MyotonPRO by three independent evaluators on the same day. The intra-class correlation (ICC) coefficients were estimated using a two-factor ANOVA to determine the inter- and intra-rater reliability. The capacity of the MyotonPRO to discriminate the viscoelastic properties of the C-Section scar against unscarred skin was assessed using the Wilcoxon signed rank test.

Results: The intra- and inter-rater reliability of the viscoelastic property measurements was good to excellent (ICC 0.99-1.00 and 0.87-0.98, respectively). There was no significant difference between C-section scar and unscarred skin in terms of elasticity (P = .737). Significant differences between C-section scars and unscarred skin tissue were observed for tone (P < .001), stiffness (P < .001), creep (P < .001), and mechanical stress relaxation time (P < .001).

Conclusion: The MyotonPRO is a reliable tool for an objective measurement of the viscoelastic properties of the C-section scar and unscarred skin. The MyotonPRO can discriminate the viscoelastic properties of the C-section scar against the unscarred skin, for tone, stiffness, creep and relaxation times, but not for elasticity.

Download full-text PDF

Source
http://dx.doi.org/10.1111/srt.12956DOI Listing

Publication Analysis

Top Keywords

unscarred skin
20
scar unscarred
16
viscoelastic properties
12
c-section scar
12
properties caesarean
8
c-section scars
8
scar
5
unscarred
5
skin
5
c-section
5

Similar Publications