A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: Network is unreachable

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Effect of an Aerosol Box on Intubation in Simulated Emergency Department Airways: A Randomized Crossover Study. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Introduction: The use of transparent plastic aerosol boxes as protective barriers during endotracheal intubation has been advocated during the severe acute respiratory syndrome coronavirus 2 pandemic. There is evidence of worldwide distribution of such devices, but some experts have warned of possible negative impacts of their use. The objective of this study was to measure the effect of an aerosol box on intubation performance across a variety of simulated difficult airway scenarios in the emergency department.

Methods: This was a randomized, crossover design study. Participants were randomized to intubate one of five airway scenarios with and without an aerosol box in place, with randomization of intubation sequence. The primary outcome was time to intubation. Secondary outcomes included number of intubation attempts, Cormack-Lehane view, percent of glottic opening, and resident physician perception of intubation difficulty.

Results: Forty-eight residents performed 96 intubations. Time to intubation was significantly longer with box use than without (mean 17 seconds [range 6-68 seconds] vs mean 10 seconds [range 5-40 seconds], p <0.001). Participants perceived intubation as being significantly more difficult with the aerosol box. There were no significant differences in the number of attempts or quality of view obtained.

Conclusion: Use of an aerosol box during difficult endotracheal intubation increases the time to intubation and perceived difficulty across a range of simulated ED patients.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7673888PMC
http://dx.doi.org/10.5811/westjem.2020.8.48901DOI Listing