98%
921
2 minutes
20
Background: Patients with heart failure with reduced left ventricular ejection fraction (LVEF) (HFrEF) experience long-term deterioration of autonomic function and cardiac electrical stability linked to increased mortality risk. The Autonomic Neural Regulation Therapy to Enhance Myocardial Function in Heart Failure (ANTHEM-HF) trial reported improved heart rate variability (HRV) and heart rate turbulence (HRT) and reduced T-wave alternans (TWA) after 12 months of vagus nerve stimulation (VNS). We investigated whether the benefits of chronic VNS persist in the long term.
Methods And Results: Effects of chronic VNS on heart rate, HRV, HRT, TWA, R-wave and T-wave heterogeneity (RWH, TWH), and nonsustained ventricular tachycardia (NSVT) incidence were evaluated in all ANTHEM-HF patients with ambulatory ECG data at 24 and 36 months (n = 25). Autonomic markers improved significantly at 24 and 36 months compared to baseline [heart rate, square root of the mean squared differences of successive normal-to-normal intervals (rMSSD), standard deviation of the normal-to-normal intervals (SDNN), HF-HRV, HRT slope, P < 0.05]. Peak TWA levels remained reduced at 24 and 36 months (P < 0.0001). Reductions in RWH and TWH at 6 and 12 months persisted at 24 and 36 months (P < 0.01). NSVT decreased at 12, 24, and 36 months (P < 0.025). No sudden cardiac deaths, ventricular fibrillation, or sustained ventricular tachycardia occurred.
Conclusion: In symptomatic patients with HFrEF, chronic VNS appears to confer wide-ranging, persistent improvements in autonomic tone (HRV), baroreceptor sensitivity (HRT), and cardiac electrical stability (TWA, RWH, TWH).
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.cardfail.2020.10.003 | DOI Listing |
Heart Rhythm
September 2025
Molecular Pharmacology and Physiology, Morsani College of Medicine, University of South Florida, Tampa, FL, United States. Electronic address:
Background: Electronic nicotine delivery systems (ENDS) utilize "E-liquids" in order to generate "E-vapor", an inhalable aerosolized mixture containing nicotine and flavors. Flavored ENDS are very popular among teens who vape, however, the possible cardiac electrophysiological harm of inhalation exposure to flavored ENDS are not fully understood.
Objective: To test if inhalation exposure to flavoring carbonyls in e-liquids compromises mitochondrial integrity, increases oxidative stress, and leads to cardiac electrophysiological toxicity.
Background: During left bundle branch area pacing (LBBAP), several markers of electrical synchrony, (V6 R-wave peak time (RWPT), aVL-RWPT, and the V6-V1 interpeak interval), are commonly used to assess left bundle branch (LBB) capture. Nevertheless, the relationship between these electrocardiographic (ECG) measurements and mechanical synchrony remains poorly understood.
Objective: We aimed to analyze the association between electrical parameters from the paced QRS complex and mechanical performance assessed through 2D strain and myocardial work (MW) indices, following LBBAP implantation.
Comput Biol Med
September 2025
Electrical and Computer System Engineering, Monash University, Clayton, Melbourne, 3800, VIC, Australia.
Congenital heart disease (CHD) is the most common type of birth defect, impacting about 1% of live births worldwide. Echocardiography, the gold-standard diagnostic method, is costly and inaccessible in low-resource settings. Diagnosis is delayed due to limited skilled experts, whose ability to interpret pathological patterns varies significantly, causing inter- and intra-clinician variability.
View Article and Find Full Text PDFSci Adv
September 2025
State Key Laboratory for Manufacturing System Engineering, State Industry-Education Integration Center for Medical Innovations, International Joint Laboratory for Micro/Nano Manufacturing and Measurement Technologies, Shaanxi Innovation Center for Special Sensing and Testing Technology in Extreme En
Continuous monitoring of cardiovascular vital signs can reduce the incidence and mortality of cardiovascular diseases, yet cannot be implemented by current technologies because of device bulkiness and rigidity. Here, we report self-adhesive and skin-conformal ultrasonic transducer arrays that enable wearable monitoring of multiple hemodynamic parameters without interfering with daily activities. A skin-adaptive focused ultrasound method with rational array design is proposed to implement measurement under wide ranges of skin curvatures and depths with improved sensing performances.
View Article and Find Full Text PDFInterdiscip Cardiovasc Thorac Surg
September 2025
Department of Electrophysiology, Abbott Inc, Chicago, IL.
We report the first use of the EnSite X system for intraoperative electrophysiological mapping during a robotic hybrid ablation (ROK-AF procedure) for long-standing persistent atrial fibrillation. Epicardial ablation targets were identified, and post-ablation electrical silencing was validated. Unlike conventional systems, its orientation-independent omnipolar technology provides directional activation vectors, high-resolution electrograms, and peak frequency analysis, thereby enhancing substrate characterisation.
View Article and Find Full Text PDF