A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Pacemaker need after sutureless aortic valve replacement: the role of the learning curve. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Aim: Aortic valve replacement (AVR) using sutureless prosthesis is a reasonable alternative in those patients with aortic stenosis who would benefit from reduced cross clamp time, such as elderly and high-risk patients. Actually, excellent performances have been demonstrated in hemodynamic outcomes and safety, but some questions remain open regarding long-term durability and the need for postoperative pacemaker implantation.

Methods: Between January 2014 and August 2019, all 436 patients [male 40.6%, median age 78 years interquartile range (73-82)] treated with sutureless AVR with a Perceval prosthesis were included in our analysis.

Results: The univariate logistic regression showed previous aortic valve surgery [P = 0.028; odds ratio (OR) 3.248], dialysis (P = 0.036; OR 6.435), renal insufficiency (P = 0.021; OR 2.75), EuroSCORE II (P = 0.016; OR 1.051) and year of operation (P < 0.01; OR 0.658) as factors associated with the development of atrioventricular type II or type III block or junctional block requiring pacemaker implantation. The overall incidence of pacemaker implantation after sutureless AVR was 7.1% in the current study, but it dropped to 3.8 and 4.7%, respectively, in 2018 and 2019.

Conclusion: The Perceval aortic valve is associated with encouraging postoperative results. The incidence of pacemaker implantation is strictly linked to the surgeons' experience, decreasing year by year after an adequate sizing, reaching a percentage comparable with sutured valve.

Download full-text PDF

Source
http://dx.doi.org/10.2459/JCM.0000000000001095DOI Listing

Publication Analysis

Top Keywords

aortic valve
12
valve replacement
8
pacemaker sutureless
4
aortic
4
sutureless aortic
4
replacement role
4
role learning
4
learning curve
4
curve aim
4
aim aortic
4

Similar Publications