STENTYS coronary system: current status and future direction.

Minerva Cardiol Angiol

Interventional Cardiology Unit, Mediterranea Cardiocentro, Naples, Italy -

Published: April 2021


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Stentys self-apposing stent was designed to face complex lesions in the precincts of percutaneous coronary interventions. Nitinol platform and disconnectable struts were designed to provide a complete apposition on the vessel wall in challenging lesions such as significant tapering, primary angioplasty in ST segment elevation myocardial infarction and bifurcation. Stentys X-position S is a sirolimus eluting stent with a novel delivery system aiming to improve positioning. Clinical trials showed good results in terms of procedural success rate, clinical outcome and short-term strut apposition. Nevertheless, Stentys stent did not show superiority over the conventional balloon-expandable stents in the clinical outcomes. Authors underlined the importance of a learning curve and an adequate training period to get familiar with the device's features. Future trials in an all-comer population using the novel X-Position S stent will confirm the preliminary findings and strengthen evidence in clinical practice.

Download full-text PDF

Source
http://dx.doi.org/10.23736/S2724-5683.20.05167-1DOI Listing

Publication Analysis

Top Keywords

stentys
4
stentys coronary
4
coronary system
4
system current
4
current status
4
status future
4
future direction
4
direction stentys
4
stentys self-apposing
4
stent
4

Similar Publications

Background: In selected patients with atrial fibrillation (AF) and impaired left ventricular ejection fraction (LVEF), catheter ablation has been proposed for rhythm control. It is unclear, if cryoballoon (CBA) or radiofrequency (RFA) ablation is the preferred technique.

Methods: The FREEZE Cohort (NCT01360008) sub-analysis included patients with LVEF < 50 % undergoing CBA (Group A) or RFA (Group B) comparing baseline characteristics, procedural data and outcome.

View Article and Find Full Text PDF

Background: Stentys drug-eluting stent (Stentys DES) was proposed to possess potential benefits over balloon-expandable platforms in large bifurcations, mainly distal left main stem (LMS). Several registries demonstrated favourable one-year clinical results of percutaneous coronary intervention (PCI) using Stentys DES for LMS disease. However, long-term follow- up data have been lacking hitherto.

View Article and Find Full Text PDF

Comparative analysis of left atrial size and appendage morphology in paroxysmal and persistent atrial fibrillation patients.

J Arrhythm

February 2025

Heart Center Munich-Bogenhausen, Department of Cardiology and Internal Intensive Care Medicine Munich Hospital Bogenhausen, Munich Municipal Hospital Group Munich Germany.

Purpose: Pulmonary vein isolation (PVI) is effective in treating atrial fibrillation (AF), but outcomes are worse for persistent AF (persAF) patients than paroxysmal AF (PAF) patients. The study aimed to identify differences in left atrial (LA) and left atrial appendage (LAA) anatomy in different AF types.

Methods: In a single-center observational study, a blinded retrospective analysis of preprocedural cardiac computed tomography angiography (CCTA) images was performed.

View Article and Find Full Text PDF

Left atrial appendage volume is an independent predictor of atrial arrhythmia recurrence following cryoballoon pulmonary vein isolation in persistent atrial fibrillation.

Front Cardiovasc Med

June 2023

Heart Center Munich-Bogenhausen, Department of Cardiology and Internal Intensive Care Medicine, Munich Hospital Bogenhausen, Munich Municipal Hospital Group, Munich, Germany.

Purpose: Pulmonary vein isolation (PVI) is the cornerstone of atrial fibrillation (AF) ablation in persistent AF (persAF), and cryoballoon PVI emerged as an initial ablation strategy. Symptomatic atrial arrhythmia recurrence following successful PVI in persAF is observed more frequently than in paroxysmal AF. Predictors for arrhythmia recurrence following cryoballoon PVI for persAF are not well described, and the role of left atrial appendage (LAA) anatomy is uncertain.

View Article and Find Full Text PDF

To investigate gender differences in epicardial adipose tissue (EAT) and plaque composition by coronary CT angiography (CCTA) and the association with cardiovascular outcome. Data of 352 patients (64.2 ± 10.

View Article and Find Full Text PDF