Stentys self-apposing stent was designed to face complex lesions in the precincts of percutaneous coronary interventions. Nitinol platform and disconnectable struts were designed to provide a complete apposition on the vessel wall in challenging lesions such as significant tapering, primary angioplasty in ST segment elevation myocardial infarction and bifurcation. Stentys X-position S is a sirolimus eluting stent with a novel delivery system aiming to improve positioning. Clinical trials showed good results in terms of procedural success rate, clinical outcome and short-term strut apposition. Nevertheless, Stentys stent did not show superiority over the conventional balloon-expandable stents in the clinical outcomes. Authors underlined the importance of a learning curve and an adequate training period to get familiar with the device's features. Future trials in an all-comer population using the novel X-Position S stent will confirm the preliminary findings and strengthen evidence in clinical practice.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.23736/S2724-5683.20.05167-1 | DOI Listing |
Int J Cardiol Heart Vasc
August 2025
Heart Center Munich Bogenhausen, Cardiology and Internal Intensive Care Medicine, Munich Municipal Hospital Group, Munich, Germany.
Background: In selected patients with atrial fibrillation (AF) and impaired left ventricular ejection fraction (LVEF), catheter ablation has been proposed for rhythm control. It is unclear, if cryoballoon (CBA) or radiofrequency (RFA) ablation is the preferred technique.
Methods: The FREEZE Cohort (NCT01360008) sub-analysis included patients with LVEF < 50 % undergoing CBA (Group A) or RFA (Group B) comparing baseline characteristics, procedural data and outcome.
Cardiol J
July 2025
First Department of Cardiology, Medical University of Gdansk, Gdansk, Poland.
Background: Stentys drug-eluting stent (Stentys DES) was proposed to possess potential benefits over balloon-expandable platforms in large bifurcations, mainly distal left main stem (LMS). Several registries demonstrated favourable one-year clinical results of percutaneous coronary intervention (PCI) using Stentys DES for LMS disease. However, long-term follow- up data have been lacking hitherto.
View Article and Find Full Text PDFJ Arrhythm
February 2025
Heart Center Munich-Bogenhausen, Department of Cardiology and Internal Intensive Care Medicine Munich Hospital Bogenhausen, Munich Municipal Hospital Group Munich Germany.
Purpose: Pulmonary vein isolation (PVI) is effective in treating atrial fibrillation (AF), but outcomes are worse for persistent AF (persAF) patients than paroxysmal AF (PAF) patients. The study aimed to identify differences in left atrial (LA) and left atrial appendage (LAA) anatomy in different AF types.
Methods: In a single-center observational study, a blinded retrospective analysis of preprocedural cardiac computed tomography angiography (CCTA) images was performed.
Front Cardiovasc Med
June 2023
Heart Center Munich-Bogenhausen, Department of Cardiology and Internal Intensive Care Medicine, Munich Hospital Bogenhausen, Munich Municipal Hospital Group, Munich, Germany.
Purpose: Pulmonary vein isolation (PVI) is the cornerstone of atrial fibrillation (AF) ablation in persistent AF (persAF), and cryoballoon PVI emerged as an initial ablation strategy. Symptomatic atrial arrhythmia recurrence following successful PVI in persAF is observed more frequently than in paroxysmal AF. Predictors for arrhythmia recurrence following cryoballoon PVI for persAF are not well described, and the role of left atrial appendage (LAA) anatomy is uncertain.
View Article and Find Full Text PDFDiagnostics (Basel)
February 2023
Department of Cardiology, Munich University Clinic, Ludwig-Maximilians-University, 80636 Munich, Germany.
To investigate gender differences in epicardial adipose tissue (EAT) and plaque composition by coronary CT angiography (CCTA) and the association with cardiovascular outcome. Data of 352 patients (64.2 ± 10.