A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Radiopaque scaffolds based on electrospun iodixanol/polycaprolactone fibrous composites. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Grafts based on biodegradable polymer scaffolds are increasingly used in tissue-engineering applications as they facilitate natural tissue regeneration. However, monitoring the position and integrity of these scaffolds over time is challenging due to radiolucency. In this study, we used an electrospinning method to fabricate biodegradable scaffolds based on polycaprolactone (PCL) and iodixanol, a clinical contrast agent. Scaffolds were implanted subcutaneously into C57BL/6 mice and monitored using longitudinal X-ray imaging and micro-computed tomography (CT). The addition of iodixanol altered the physicochemical properties of the PCL scaffold; notably, as the iodixanol concentration increased, the fiber diameter decreased. Radiopacity was achieved with corresponding signal enhancement as iodine concentration increased while exhibiting a steady time-dependent decrease of 0.96% per day . The electrospun scaffolds had similar performance with tissue culture-treated polystyrene in supporting the attachment, viability, and proliferation of human mesenchymal stem cells. Furthermore, implanted PCL-I scaffolds had more intense acute inflammatory infiltrate and thicker layers of maturing fibrous tissue. In conclusion, we developed radiopaque, biodegradable, biocompatible scaffolds whose position and integrity can be monitored noninvasively. The successful development of other imaging enhancers may further expand the use of biodegradable scaffolds in tissue engineering applications.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7497787PMC
http://dx.doi.org/10.1016/j.mtla.2020.100874DOI Listing

Publication Analysis

Top Keywords

scaffolds based
8
scaffolds
8
position integrity
8
biodegradable scaffolds
8
concentration increased
8
radiopaque scaffolds
4
based electrospun
4
electrospun iodixanol/polycaprolactone
4
iodixanol/polycaprolactone fibrous
4
fibrous composites
4

Similar Publications