A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

The geometric mean is a superior frequency response averaging method for human body vibration. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

The frequency response data of human body vibration are often used for standardisation, design of transport vehicles and occupational health and safety measures. This article shows that the commonly used methods of averaging frequency response spectra, such as arithmetic averaging in the complex or magnitude domain and median averaging, are not as suitable as the less commonly used geometric averaging in the complex domain. This is because it is necessary to minimise the deviation of the measured values about the mean value and to minimise the bias from the true mean value due to noise, distortion and nonlinearity. : For averaging frequency response spectra, it is necessary to minimise the bias from the true mean value. This research shows that the commonly used averaging methods, such as arithmetic averaging in the complex or magnitude domain and the median, are not as suitable as geometric averaging in the complex domain. H1 Estimator: frequency response function estimation method using the cross-spectrum of the output with the input divided by the auto-spectrum of the input; ISO: International Organization for Standardization; NHK: Nippon Hatsujo Kabushiki Kaisha; PCB: PCB Group ("PCB" is abbreviation for "PicoCoulomB"); RMIT: Royal Melbourne Institute of Technology; r.m.s.: root mean square.

Download full-text PDF

Source
http://dx.doi.org/10.1080/00140139.2020.1820584DOI Listing

Publication Analysis

Top Keywords

frequency response
20
averaging complex
16
averaging
9
human body
8
body vibration
8
averaging frequency
8
response spectra
8
arithmetic averaging
8
complex magnitude
8
magnitude domain
8

Similar Publications