Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 317
Function: require_once
98%
921
2 minutes
20
Venoarterial extracorporeal membrane oxygenation (VA-ECMO) serves as a conventional short-term mechanical circulatory assist to support heart and lung functions. The short-term ventricular assist devices (ST-VAD) can, on the contrary, offer only circulatory support. A combination of VAD and oxygenator (Oxy-VAD) could help overcome this potential disadvantage. This is a retrospective case note study of patients supported on ST-VAD which required adding an oxygenator for extra respiratory support. The oxygenator was introduced in the ST-VAD circuit, either on the left or the right side. Twenty-two patients with the etiology of refractory cardiogenic shock in decompensation were supported on Oxy-VAD between years 2009 and 2019 at tertiary care . All patients were classified into class-I INTERMACS with a mean SOFA Score of 14 ± 2.58. 86.4% of patients were already on mechanical support pre-ST-VAD implant, 80% on VA-ECMO. The BiVAD implant accounted for 63.6%, followed by LVAD and RVAD with 27.3% and 9.1%. Mean duration of the ST-VAD was 8.5 days. The oxygenator was introduced in 14 RVAD and 8 LVAD circuits. The oxygenator was successfully weaned in 54.5% while ST-VAD was explanted in 31.8%. Discharge to home survival was 22.7%. Oxy-VAD proves a viable, and probably, a better option to VA-ECMO in acute cardiorespiratory decompensation. It offers organ-specific tailor-made support to the right and/or left heart and/or lungs. While on Oxy-VAD support, each organ performance can be assessed independently, and the assistance of the specifically improved organ can be weaned off without discontinuing the support for the rest.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/aor.13813 | DOI Listing |