A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Metal Nanozyme with Ester Hydrolysis Activity in the Presence of Ammonia-Borane and Its Use in a Sensitive Immunosensor. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Metal nanoparticle surfaces are used for peroxidase- and oxidase-like nanozymes but not for esterase-like nanozymes. It is challenging to obtain rapid catalytic hydrolysis on a metal surface and even more so without a catalytically labile substrate. Here, we report that metal nanoparticle surfaces rapidly catalyze non-redox ester hydrolysis in the presence of redox H N-BH (AB). Metal hydrides are readily generated on a Pt nanoparticle (PtNP) from AB, and as a result the PtNP becomes electron-rich, which might assist nucleophilic attack of H O on the carbonyl group of an ester. The nanozyme system based on PtNP, AB, and 4-aminonaphthalene-1-yl acetate provides an electrochemical signal-to-background ratio much higher than natural enzymes, due to the rapid ester hydrolysis and redox cycling involving the hydrolysis product. The nanozyme system is applied in a sensitive electrochemical immunosensor for thyroid-stimulating hormone detection. The calculated detection limit is approximately 0.3 pg mL , which indicates the high sensitivity of the immunosensor using the PtNP nanozyme.

Download full-text PDF

Source
http://dx.doi.org/10.1002/anie.202009737DOI Listing

Publication Analysis

Top Keywords

ester hydrolysis
12
metal nanoparticle
8
nanoparticle surfaces
8
nanozyme system
8
metal
5
hydrolysis
5
metal nanozyme
4
ester
4
nanozyme ester
4
hydrolysis activity
4

Similar Publications